59EN
cod. 3540000272 - Rev. 01 - 01/2024
If the room temperature is lower than the required value, it is advisable to set a higher order curve
and vice versa. Proceed by increasing or decreasing in steps of one and check the result in the
room.
Adjustments from Remote Timer Control
A
If the boiler is connected to the Remote Timer Control (optional), the previously described
adjustments are managed as described in table 1.
Table 1
fig. 14- Compensation curves
fig. 15- Example of compensation parallel
curve offset
Heating temperature adjustment
Adjustment can be made from the Remote Timer Control menu and the
boiler control panel.
DHW temperature adjustment
Adjustment can be made from the Remote Timer Control menu and the
boiler control panel.
Summer/Winter Switchover
Summer mode has priority over a possible Remote Timer Control heating
request.
Eco/Comfort selection
On disabling DHW from the Remote Timer Control menu, the boiler selects
Economy mode. In this condition, the eco/comfort button on the boiler
panel is disabled.
By enabling DHW from the Remote Timer Control menu, the boiler selects
the Comfort mode (if previously enabled from the boiler panel). In this con-
dition it is possible select one of the two modes on the boiler panel.
Sliding Temperature You can make all the adjustments by using the remote timer control.
20
30
40
50
60
70
80
90
85
20 10 0 -10 -20
1
2
3
4
5
68910 7
20
30
40
50
60
70
80
90
85
20
30
40
50
60
70
80
90
85
1
2
3
4
5
6
8910
7
1
2
3
4
568910 7
OFFSET = 20
OFFSET = 40