ECONCEPT TECH 35 A
9EN
cod. 3540I341 - 04/2008 (Rev. 00)
Press the heating buttons (details 3 and 4 - fig. 1) to access parallel curve offset; "OF" appears flashing
(fig. 11). Operate the DHW buttons (details 1 and 2 - fig. 1) to adjust parallel curve offset according to the
characteristic (fig. 13).
fig. 11 - Parallel curve offset
Press the button (detail 6 - fig. 1) again for 5 seconds to exit the “Sliding Temperature” menu.
If the room temperature is lower than the required value, it is advisable to set a higher order curve and vice versa. Pro-
ceed by increasing or decreasing in steps of one and check the result in the room.
fig. 12 - Compensation curves
fig. 13 - Example of parallel compensation curve shift
A
If the Remote Timer Control (optional) is connected to the boiler, the above adjustments are managed accord-
ing to that given in table 1.