Place the mobile dust extractor in a dry room in-
accessible to unauthorised users.
Emptying the dust container
The dust container
[2-3]
can be emptied once the
top section has been removed.
After extracting fluids, clean the fill level sen-
sors
[10-1]
regularly with a soft cloth and in-
spect for damage.
Service and maintenance
A dust test must be performed at least once a year by
the manufacturer or an instructed person. This test
may include checks to determine whether the filter is
damaged, the machine is sealed properly and the
monitoring features are functioning correctly.
During maintenance and repair work, all components
that cannot be cleaned satisfactorily must be re-
placed. The old components must be sealed in imper-
meable plastic bags prior to disposal in compliance
with applicable regulations for this type of waste.
Customer service and repair
only
through manufacturer or service
workshops: Please find the nearest
address at:
www.festoolusa.com/service
Use only original Festool spare parts!
Order No. at:
www.festoolusa.com/service
Accessories
Use only original Festool accessories and Festool
consumable material intended for this machine be-
cause these components are designed specifically
for the machine. Using accessories and consum-
able material from other suppliers will most likely
affect the quality of your working results and limit
any warranty claims. Machine wear or your own
personal workload may increase depending on the
application. Protect yourself and your machine, and
preserve your warranty claims by always using
CAUTION
Hazardous dust
Damage to the respiratory passage
Wipe down the mobile dust extractor and clean all
accessories thoroughly using the extractor (inside
and out) before removing from the working area.
Parts that you were not able to clean thoroughly
must be sealed in an airtight plastic bag prior to
transportation.
Wear a dust mask!
10-1 10-1
10
WARNING
Any maintenance or repair work that requires open-
ing of the motor or gear housing should only be car-
ried out by an authorised Customer Service Centre
(name supplied by your dealer)!
Maintenance or repair work carried out by an unau-
thorised person can lead to the wrong connection of
the power leads or other components, which in turn
can lead to accidents with serious consequences.
WARNING
To prevent accidents, always remove the plug
from the power supply socket before carrying out
any maintenance or repair work on the tool!
Do not use compressed air to clean the electrical
tool! Do not try to clean parts inside the tool in
this way, as you could let foreign objects in
through the openings of the tool housing.
EKAT
1
2
3
5
4

Other manuals for Festool CT 26 E HEPA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festool CT 26 E HEPA and is the answer not in the manual?

Festool CT 26 E HEPA Specifications

General IconGeneral
ModelCT 26 E HEPA
CategoryVacuum Cleaner
Power Consumption1200 W
Max Vacuum24 kPa
Container Volume26 l
Filter TypeHEPA
Automatic Filter CleaningYes
Hose Length3.5 m
Cord Length7.5 m
Max Vacuum Pressure24 kPa
Airflow4200 l/min