EasyManuals Logo

FIBARO FGMS-001 User Manual

FIBARO FGMS-001
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
8
OPERATING THE DEVICE
Resetting the Motion Sensor:
Reset procedure erases the memory, including all information on the
Z-Wave network and the main controller.
1. Open the cover.
2. Press and hold the B-button.
3. Wait for visual indicator to glow yellow (2nd menu position).
4. Release the B-button.
5. Click the B-button to conrm selection.
6. After few seconds the device will be reset, which is signalled with
the red, fading visual indicator colour.
NOTE
Resetting the device is
not the recommend-
ed way of removing
the device from the
Z-Wave network. Use
reset procedure only if
the primary controller
is missing or inopera-
ble. Certain device re-
moval can be achieved
by the procedure of
removing described in
Adding/removing the
device on page 6.
i
Seismograph mode:
The Motion Sensor can be congured to work as a simple earthquake
detector, by setting the parameter 24 value to 1. Reports with scale of
the vibrations (in the Modied Mercalli Scale) will be sent immediate-
ly after vibrations have been detected. Minimal power of vibrations
that will be reported, can be set in parametr 20. Once the vibrations
cease and time of sustaining alarm elapses, reports will be stopped.
Orientation in space:
The Motion Sensor has a built-in accelerometer. When the parameter 24
is set to 2, Z-Wave network controller will be informed on the Sensors
orientation in space by sending report after triggering tamper alarm.
Notication report:
The device uses Notication Command Class to report dierent events.
Notication Type Event
Home Security Tampering, product covering removed
Home Security Motion Detection, unknown location
NOTE
Command Class Basic
value is related to the
status of motion sensor
(0x00 - no motion, 0xFF
- motion detected).
i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FIBARO FGMS-001 and is the answer not in the manual?

FIBARO FGMS-001 Specifications

General IconGeneral
Sensor type-
Connectivity technologyWireless
Maximum range50 m
Battery typeCR123A
CertificationLVD 2006/95/WE, EMC 2004/108/WE, R&TTE 1999/5/WE, RoHS II
Product colorWhite
Operating temperature (T-T)0 - 40 °C