EasyManua.ls Logo

Field Controls UV-AIRE UV-1500C - User Manual

Field Controls UV-AIRE UV-1500C
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
www.fieldcontrols.com
Please retain these instructions after installation.
This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for
use in the mitigation, treatment, or prevention of any disease or condition.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
Installation Date:
Installed By: Phone:
UV-AIRE
®
AIR PURIFYING SYSTEM
Model: UV-1500C
ITEMS INCLUDED IN KIT:
1- UV-Aire UV-1500 unit
10- sheet metal mounting screws
2- drop ceiling cover plates
4- wall and drop ceiling mounting brackets
1- Ultra Violet lamp
1- instruction sheet
1- 2x4 electrical conduit box and cover
4- intake air filters
1- carbon filter
*For best results, operate the UV-1500
continuously 24 hours a day.
UV-C light inhibits the growth and reproduction of germs and bacteria in the air of a home or office. The
treatment is a safe, silent, and proven way to make your home or office a healthier place to live and work.
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.
SAFETY CONSIDERATIONS
WARNING: Never expose eyes or skin to UVC light from any source.
•LookingdirectlyattheUVClightmaycausepermanenteyedamageorblindness.
•NeveroperatetheUV-AireAirPurifyingSystemwiththeUVchamberopen.
WARNING: DO NOT mount this unit outdoors.
•Thisproductisdesignedforindoorinstallationonly.

Questions and Answers

  • W
    wrightsamanthaJul 26, 2025
    What to do if Field Controls UV-AIRE UV-1500C LED is red?
    • B
      Brian WalkerJul 26, 2025
      If the LED on your Field Controls Air Cleaner is illuminating red and the circuit board alarm beeps every 5 minutes, the lamp should be replaced.
  • J
    Janice TaylorAug 2, 2025
    What to do if Field Controls UV-AIRE UV-1500C LED is yellow?
    • N
      nicholaswalkerAug 2, 2025
      If the LED on your Field Controls Air Cleaner is illuminating yellow and the circuit board alarm beeps every 15 minutes, the lamp should be replaced soon.
  • D
    davidpattonAug 9, 2025
    How to fix Field Controls UV-AIRE UV-1500C Air Cleaner when the lamp does not light up?
    • M
      Mary FieldsAug 9, 2025
      If the lamp in your Field Controls Air Cleaner does not light up: - Ensure that the safety switch located in the carbon filter chamber is depressed with pressure from the filter. - If the safety switch is correctly positioned, replace the lamp.
  • L
    lee97Aug 17, 2025
    What to do if Field Controls UV-AIRE UV-1500C lamp still does not light up?
    • J
      jtylerAug 17, 2025
      If the lamp in your Field Controls Air Cleaner still does not light up after checking the safety switch and replacing the lamp, replace the ballast.

Summary

Safety Considerations

UVC Light Exposure Warning

Warns against exposing eyes or skin to UVC light, which can cause permanent eye damage or blindness.

Outdoor Mounting Prohibition

Explicitly states the unit is designed for indoor installation only and must not be mounted outdoors.

UV-1500 C Check Out Procedure

Wall Mounting Option

Suspension or Drop Ceiling Option

Suspension or Drop Ceiling Installation Continued

UV Lamp Replacement Procedures

Accessing and Removing the UV Lamp

Guides on opening the unit, releasing clips, unplugging the ballast, and carefully sliding the old lamp out.

UV Lamp Replacement Procedures Continued

Air Filter Replacement

Troubleshooting Guide

LED Status and Alarm Diagnosis

Addresses issues indicated by yellow/red LEDs and alarms, suggesting lamp replacement or ballast replacement.

Lamp Not Lighting Diagnosis

Helps diagnose why the lamp might not be lighting, checking the safety switch and considering ballast failure.

Field Controls UV-AIRE UV-1500C Specifications

General IconGeneral
ModelUV-1500C
ApplicationHVAC systems
Voltage120V
Frequency60Hz
Lamp Wattage15W
Wattage15W
Coverage AreaUp to 1500 sq. ft.
Weight5 lbs
InstallationProfessional Installation Recommended
Product TypeUV Air Cleaner
CategoryAir Cleaner
Power SupplyElectric
Lamp TypeUV Lamp

Related product manuals