www.fieldcontrols.com
Please retain these instructions after installation.
This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for
use in the mitigation, treatment, or prevention of any disease or condition.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
Installation Date:
Installed By: Phone:
UV-AIRE
®
AIR PURIFYING SYSTEM
MODEL: UV-18X
ITEMS INCLUDED IN KIT:
1-UV-Aire
power unit
4-Sheet metal mounting screws
2-Angled mounting brackets
2-Flat mounting brackets
1-Duct board mounting bracket
2-Ultra Violet lamps
1-Instruction Sheet
2-Wing nuts
Caution Labels
Gasket
SAFETY CONSIDERATIONS
WARNING: Never expose eyes or skin to UV-C light from any source.
Looking directly at the UV-C light may cause permanent eye damage or blindness.
•
Never operate the UV-Aire Air Purifying System out of the plenum.•
Designed for a closed duct system. Do not mount near a return air opening•
All duct openings in direct line of site of the UV light must be sealed with duct tape or equivalent •
sealing methods.
WARNING: UV light will break down plastic materials not rated for UV exposure:
(Examples: wire insulation, flex duct, drain pans and humidifiers)
The unit must be mounted at least 30” from the above stated type of materials.
•
If it is necessary to mount the unit in direct line of sight of these types of materials, they must be •
shielded with aluminum foil, aluminum foil tape, or sheet metal.
WARNING: DO NOT mount this unit outdoors.
This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.).
•
UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a homes
heating and air conditioning system. The treatment is a safe, silent, and proven way to make your home a
healthier place to live.
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.
Question and Answer IconNeed help?

Do you have a question about the Field Controls UV-Aire UV-18X and is the answer not in the manual?

Field Controls UV-Aire UV-18X Specifications

General IconGeneral
ModelUV-18X
CategoryAir Cleaner
Lamp TypeUV-C
Lamp Wattage18W
Voltage120V
Frequency60Hz
Weight5 lbs
ApplicationResidential and Commercial HVAC systems
Warranty1 year
Product TypeAir Cleaner

Summary

Safety Considerations for UV-Aire System

UV-C Exposure and Operation Warning

Never expose eyes or skin to UV-C light; avoid direct exposure and operating unit outside the plenum.

Material Degradation and Shielding Warning

UV light degrades certain plastics; shield affected materials or mount unit 30" away.

Outdoor Installation Prohibition

This unit is designed for indoor installation only, not for outdoor use.

General Information and Specifications

Product Specifications Overview

Details on model, duct width, voltage, amps, Hz, watts, max air temp, and lamp intensity.

Installation Procedures

Site Selection and Placement

Guidance on choosing an installation location in the supply or return plenum for optimal unit placement.

Flex Duct Installation

Instructions for installing the UV-Aire unit on duct systems with metallic main duct and flex duct branches.

Metal Duct Installation

Steps for mounting the unit onto a metal air duct using a template and cutting a precise opening.

Duct Board Installation

Procedure for mounting the unit onto duct board, involving cutting and securing the mounting plate.

Unit Mounting and Lamp Installation

Details on securing the unit base to the duct, handling the lamp, and connecting the ballast.

Final Connection and Testing

Steps for replacing the cover, plugging in the power cord, and verifying the lamp operation.

Bracket Selection and Specifications

Bulb Mounting Bracket Options

Guidance on choosing between angled and flat mounting brackets based on duct size and needs.

Angled Lamp Mounting Bracket Specs

Specifications for allowable clearances for mounting the UV-Aire unit using an angled bracket.

Maintenance and Troubleshooting

Regular Maintenance Schedule

Recommendations for inspecting and cleaning the lamp every six months.

Lamp Replacement Procedure

Step-by-step guide for safely removing and replacing the UV lamp, including handling precautions.

Troubleshooting Unit Not Lighting

Guidance on diagnosing and resolving issues where the unit does not light up, starting with bulb replacement.

Parts and Warranty Information

Replacement Parts List

List of model numbers for replacement lamps and ballasts, with contact information.

Limited Warranty Terms

Details on the warranty period for products, provisions for repair/replacement, and disclaimers.

Related product manuals