display type | LCD |
---|---|
analog bar graph segments | 34 |
measurement rate | 20 times per second |
operating temperature | 32°F to 122°F |
---|---|
storage temperature | -4°F to 140°F |
altitude | 6561.7 Feet |
power source | 9-volt battery |
---|---|
battery life | 300 hours |
auto power off | Approx. 10 minutes |
DC voltage ranges | 340mV, 3400mV, 34V, 340V, 600V |
---|---|
DC voltage resolution | 0.1mV |
AC voltage ranges | 3.4V, 34V, 340V, 600V |
AC current ranges | 34A, 300A |
---|---|
AC current resolution | 0.01A |
DC current ranges | 340μA, 3400μA |
resistance ranges | 340Ω, 3.4kΩ, 34kΩ, 340kΩ, 3.4MΩ, 34MΩ |
---|---|
resistance resolution | 100mΩ |
open circuit volts | -0.45VDC typical |
temperature range | -30°F ~ 1000°F, -35°C ~ 600°C |
---|---|
temperature resolution | 0.1°F, 0.1°C |
sensor type | K-type thermocouple |
Meter works with Fieldpiece accessory heads for expanded measurement capabilities.
Detects AC voltage via NCV function, lighting LED and beeping for alerts.
Beeps and blinks red LED when voltage exceeds 30V, providing a warning.
Features a longer fixed jaw for easier single wire selection in bundles.
Used for measuring flame diode current in heater controls.
Suitable for measuring motor-start and motor-run capacitors.
Uses K-type thermocouple for accurate temperature readings in dynamic environments.
Allows display of temperature in Celsius (°C) or Fahrenheit (°F) via jumper.
Procedure for calibrating temperature readings to within ±1°F using ice water.
Tips for using and storing silicone test leads for flexibility and durability.
Essential precautions for safe operation, including test lead inspection and isolation.
Explanation of symbols indicating caution, manual reference, and double insulation.
Guidelines for cleaning the exterior and replacing the 9V battery.
Details on the LCD display, analog bar graph, and measurement update rate.
Specifies acceptable temperature and humidity ranges for operation and storage.
Defines accuracy standards, temperature coefficients, and altitude limitations.
Information on battery type, battery life, and standard accessories provided.
Ranges, resolution, accuracy, input impedance, and overload protection for DCV.
Ranges, resolution, accuracy, input impedance, and overload protection for ACV.
Ranges, resolution, accuracy, and overload protection for ACA.
Ranges, resolution, accuracy, voltage burden, and overload protection for DCA.
Ranges, resolution, accuracy, open circuit volts, and overload protection for Resistance.
Details on test current, resolution, accuracy, open circuit volts, and indication.
Information on audible indication, response time, and LED status for continuity.
Ranges, resolution, accuracy, test frequency, voltage, and overload protection.
Ranges, resolution, accuracy, sensor type, and overload protection for temperature.
Indicates meter beeps and red LED blinks for voltages >30VAC/DC.
Senses AC voltage from 24V to 600V, activating beeper and LED.
Covers defects in material/workmanship for one year, subject to terms.