EasyManua.ls Logo

Filtec ft-70 - Aligning the Inspection Trigger (Cans)

Default Icon
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-70/75 Fill Level Inspectors Operator’s Guide
2-22
Aligning the Inspection Trigger (Cans)
Figure 2-11. Aligning the Inspection Trigger Beam (Cans).
You must align the inspection trigger height so that the trigger
beam contacts the container at the widest part of the lid.
1. Turn off the Safety Interlock Switch. For more information see
“The Safety Interlock Switch” on page 2-4.
2. Loosen the Centerline Trigger Bracket Height Lock, and using
the Centerline Trigger Bracket Height Crank, raise the bracket
all the way.
1
3
5
4
7
6
8
2
7
6
9
No. Description
1 Trigger Height Lock
2 Trigger Beam Emitter
3 Trigger Beam Centerline
4 Trigger Beam Receiver
5 Container Travel
6 Trigger Horizontal Centerline
7 Trigger Vertical Centerline
8 Width of Container at Trigger Point (top up)
9 Width of Container at Trigger Point (bottom up)
Industrial Dynamics Company, Ltd. Document 40274-0600