FT-70/75 Fill Level Inspectors Operator’s Guide
5-4
120 Day Maintenance
Inspect Nameplate, Stickers, and Instruction Plates
Inspect Inspection Head Housing for dirt and moisture
Service Pneumatic components per Rejector Manual
Lubricate All Trigger Raising Mechanism lead screws and ways
Action Description
Inspect Inspection Head Housing for dirt and moisture
Inspect Wiring, insulation, terminals, and terminal blocks inside
the Inspection Head and External Junction Box.*
Inspect X-ray Emitter and Detector aperatures for damage
blockage.
*Not all units are equipped with the optional External Junction Box.