5. LCD Controller Display
1.
2. Press Mto choose the mode
Press "M"again cooling
Press "M"again heating
3. Standby status:
Press "M" 5 seconds,get a soundB ,LCD display will show0"27 SET to enter cooling
temp. setting,press to alter cooling temp.PressSETagain to confirm.
Press "M"again "1" "27"
Press "M"again "2" "40"
Under running status, press to adjust the temperature.
.Press
PressSET to enter heating temp. setting,press to alter heating temp.
PressSETagain to confirm.
PressSET to enter defrosting time setting,press to alter defrosting time.
PressSETagain to confirm.
Swimming pool Heat Pump
5.1 Setting step
3
10
Press "M"again "3" "-7" Press “SET” to enter defrosting temp. setting,press to alter defrosting temp.
Press “SETagain to confirm.
Press "M"again "4" "13 " Press “SET” to enter exit defrosting temp. setting,press to alter exit defrosting temp.
Press “SETagain to confirm.
Press "M"again "5" "8 " Press “SET” to enter exit defrosting time setting,press to alter exit defrosting
time.Press “SETagain to confirm.
Press "M"again "6" "1 " Press “SET” to enter system quantity setting,press to alter system quantity.
Press “SETagain to confirm.
Press "M"again "7" "1 " Press “SET” to enter Automatic setting,press to alter.Press “SETagain to confirm.
Press "M"again "8" "1 " Press “SET” to enter Mode setting,press to alter.Press “SETagain to confirm.
Press "M"again "9" "0 " Press “SET” to enter water pump setting,press to alter.Press “SETagain to confirm.
Press "M"again "A" "40 " Press “SET” to enter return water temp. setting,press to alter .Press “SETagain
to confirm.
Press "M"again "b" "5 " Press “SET” to enter Overheat protection(heating mode) setting,press to alter.
Press “SETagain to confirm.
Press "M"again "C" "35 " Press “SET” to enter Electronic expansion valve setting,press to alter.
Press “SETagain to confirm.
Press "M"again "D" "5 " Press “SET” to enter Overheat protection(cooling mode) setting,press to alter.
Press “SETagain to confirm.
Press "M"again "E" "40 " Press “SET” to enter Max. temp. setting,press to alter.Press “SETagain to confirm.
Press "M"again "F" "2 " Press “SET” to enter Split temp. setting,press to alter.Press “SETagain to confirm.
Press "M"again "G" "-10 " Press “SET” to enter Ambient temp. protection setting,press to alter.
Press “SETagain to confirm.
Further explanation of PCB connections (refer P14 on user manual).
4.Clock setting
Under running or standby status,Press “SET” for 5 seconds,get a sound “B,press to alter hour,press “SETagain
to alter minute.Press “SETagain to confirm.
5.Timer setting
Under running or standby status,Press “ ” for 5 seconds,get a sound “B,press to alter hour of timer ON,Press
“ ”again to alter minute of timer ON.Press “ ” again to alter timer OFF.