EasyManua.ls Logo

Fimco LG-25-DLX-SP - User Manual

Fimco LG-25-DLX-SP
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1
Technical Specifications
25 Gal. Corrosion-Resistant Polyethylene Tank
12 Volt Diaphragm Pump, 2.4 GPM - 60 PSI
20 Ft. Handgun Hose (3/8” I.D.)
Pressure Gauge (Adjustable Pressure)
Bypass (Recirculation) Line
Assembly Instructions
Your sprayer has been mostly assembled at the factory. One
requirement will before you to hook up your battery leads to a
fully charged 12 Volt battery.
Remove the handgun clips from the parts bag and place them
onto the tank as shown.
Remove the Pressure Gauge from the parts bag and thread it
into the manifold assembly. Use a good grade of thread seal-
ant or plumber’s tape to ensure no leaks.
Caution: When fully filled with water, this sprayer will
weigh 240 lbs.. Consult the owner’s manual for your
vehicle to verify that you are within it’s load carrying
capacity.
www.fimcoindustries.com
1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD 57049
Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440
[5195127 (02/19)]
Model: LG-25-DLX-SP
(5302938)
(25 Gallon Deluxe Spot Sprayer)
***IMPORTANT REMINDER***
This sprayer comes with an On/Off (shut-off) valve located at the inlet location
of the tank, towards the underside. (See Detail A). You must make sure the
valve is in the “open” position before using your sprayer.
Detail A
OWNER’S MANUAL
BEFORE RETURNING THIS PRODUCT
FOR ANY REASON, PLEASE CALL
1-800-831-0027
MONDAY-FRIDAY, 8:00 AM TO 5:00 PM CST
If you should have a question or experience a problem with
your Fimco Industries Product: Visit our website @
www.fimcoindustries.com or call the Toll free number above. Our
technical support representatives will be happy to help you.
In most cases a customer service rep. can resolve
the problem over the phone.
To obtain prompt, efficient service, always remember to give the
following information....
• Correct Part Description and/or part number
• Model number and Serial Number
Part descriptions and numbers can be obtained from the
illustrated parts list section(s) of this manual.
General Information
Thank you for purchasing this product. The purpose of this
manual is to assist you in operating and maintaining your lawn
& garden spot sprayer.
Retain a copy of your receipt for your
unit, as it will be required to validate
any warranty service.
Warranted against manufacturer or
workmanship defects from date of
purchase with copy of receipt:
Homeowner Usage: Sprayer-One Year and Pump-Two Years.
Commercial Usage: Sprayer and Pump-90 Days.

Questions and Answers

Summary

General Information

Safety, Support, and Warranty

Read manual, heed warnings, contact Fimco for support, and retain receipt for warranty.

Technical Specifications

Assembly Instructions

Initial Assembly Steps

Attach handgun clips, thread pressure gauge, and check vehicle load capacity for filled sprayer.

Testing the Sprayer

Pre-Test Preparation

Ensure tank is clean and free of foreign material. Rinse tank before filling with plain water for testing.

Testing Procedure

Steps for testing sprayer leaks, adjusting pressure via bypass valve, and confirming spray pattern.

Operation

Power Connection and Operation

Connect 12V battery leads correctly. Use the On/Off switch to activate the pump.

Spraying and Pressure Control

Initiate spraying by handgun trigger or bypass valve. Adjust pressure using the bypass valve.

Maintenance During;After Spraying

Routine Maintenance and Flushing

Periodically check strainer. Flush system with water and cleaner after use.

Chemical Handling Warning

Warning against leaving chemicals in pump and importance of flushing pump after each use.

Winter Storage

Troubleshooting

Pump Model and Parts

Pump Model Identification

Identifies the pump model as 5281371 and lists available replacement parts with part numbers.

Pump Operation Guidelines

Provides DOs and DON'Ts for pump usage, including cleaning, winterizing, and prohibited substances.

Pump Troubleshooting

Motor Not Running or Priming

Troubleshooting steps for pump motor not running or failing to prime, checking wiring, fuse, and switches.

Pulsating Flow and Continuous Running

Addresses pulsating flow (surging) and motor continuously running after discharge shut-off.

Low Pressure;Flow and Fuse Issues

Diagnoses low pressure/flow issues and blown fuses, suggesting checks for voltage, leaks, and wiring.

Checking the Pressure Switch

Cleaning the Check Valve

Intake;Siphon Tube Detail

Siphon Tube and Shut-Off Valve

Details the siphon tube and shut-off valve placement for intake and cleaning access.

Checking;Cleaning Filter;Screen

Procedure for checking and cleaning the sprayer's intake filter/screen via the shut-off valve.

Exploded View;Parts List

Exploded View Diagram

Diagram showing all sprayer components with reference numbers for identification.

Parts List

Detailed list of sprayer parts with reference numbers, part numbers, descriptions, and quantities.

Warranty

Limited Warranty Terms

Details limited warranty coverage, duration for sprayer and pump, and exclusions.

Obtaining Warranty Service

Instructions on how to obtain warranty service, including notice requirements and contact information.

Remedies and Limitations

Outlines available remedies, limitations on implied warranties, and exclusion of incidental damages.

Fimco LG-25-DLX-SP Specifications

General IconGeneral
BrandFimco
ModelLG-25-DLX-SP
CategoryPaint Sprayer
LanguageEnglish

Related product manuals