Technical Specifications
30 Gal. Corrosion-Resistant Polyethylene Tank
12 Volt Diaphragm Pump, 2.4 GPM - 60 PSI
20 Ft. Handgun Hose
25 Ft. max. vertical throw, 35 Ft. horizontal throw
3-Nozzle Break-Away Boom Assembly
Corrosion-Resistant Nylon Nozzles
Check Valve Strainers, 50 Mesh, 5 PSI
Easy access drainage port (Complete Drain Out)
Front forward gun and hose wrap for easier
access from transport vehicle
Heavy Duty 16” tires
Wide Axle
Streamlined tank design for compact storage and
shorter turning radius
Caution: Always check the vehicle load rating before
using the sprayer. The loaded weight of this sprayer and
boom assembly is approx.: 320 lbs. when the tank is full.
Assembly Instructions
Make sure the contents of the sprayers carton match the
items shown on page 2 of the manual.
Follow the steps on pages 3 & 4 to properly assemble the
sprayer.
IMPORTANT:
This sprayer comes with
an On/Off (shut-off) valve
located at the inlet location
of the tank, towards the
underside. You must
make sure the valve is in
the “open” position before
using your sprayer.
OWNER’S MANUAL
BEFORE RETURNING THIS PRODUCT
FOR ANY REASON, PLEASE CALL
1-800-831-0027
MONDAY-FRIDAY, 8:00 AM TO 5:00 PM CST
If you should have a question or experience a problem with
your Fimco Industries Product: Visit our website @
www.fimcoindustries.com or call the Toll free number above. Our
technical support representatives will be happy to help you.
In most cases a customer service rep. can resolve
the problem over the phone.
To obtain prompt, efficient service, always remember to give the
following information....
• Correct Part Description and/or part number
• Model number and Serial Number
Part descriptions and numbers can be obtained from the
illustrated parts list section(s) of this manual.
General Information
Thank you for purchasing this product. The purpose of this
manual is to assist you in operating and maintaining your lawn
& garden Trailer sprayer.
Retain a copy of your receipt for your
unit, as it will be required to validate
any warranty service.
Warranted against manufacturer or
workmanship defects from date of
purchase with copy of receipt:
Homeowner Usage: Sprayer-One Year and Pump-Two Years.
Commercial Usage: Sprayer and Pump-90 Days.

Questions and Answers

  • S
    Suzanne FordAug 8, 2025
    What to do if the Fimco LG-30-3N-TRL motor does not run?
    • T
      Tasha JacksonAug 8, 2025
      If the motor of your Fimco Paint Sprayer isn't running, here are a few things to check: * Ensure there are no loose wiring connections. * Verify the 'ON/OFF' switch in the lead wire assembly is in the 'ON' position ('I' is 'ON', 'O' is 'OFF'). * Check the fuse. * Make sure you are connected to a good 12 volt power source and check for low voltage at the power supply. * Inspect the pressure switch. Remove the cap and detach both red wires from their terminals, then touch the two ends together. If the pump runs, the pressure switch needs replacement.
  • M
    Melanie HeathAug 13, 2025
    How to fix low pressure or low flow in my Fimco LG-30-3N-TRL?
    • W
      williamsdanielAug 13, 2025
      To address low pressure or low flow in your Fimco Paint Sprayer, consider the following: * Check for any leaks or restrictions in the discharge line. * Inspect the nozzle orifice for debris. * Ensure the strainer isn't clogged. * Verify you're using the proper voltage, and try another 12-volt battery.
  • D
    Daniel McbrideAug 18, 2025
    Why is the flow pulsating or surging in my Fimco LG-30-3N-TRL?
    • J
      Jon WadeAug 18, 2025
      A pulsating or surging flow in your Fimco Paint Sprayer can be due to several reasons: * Low flow may cause the pump to surge. * The spray wand might be adjusted for a small or fine spray pattern. * There might be leaks or restrictions in the discharge line. * Debris in the nozzle orifice or a clogged strainer could be the issue. * The discharge hose might be too long. To resolve this, slightly open the bypass (if your sprayer has one). If needed, adjust the pressure switch a quarter turn clockwise until the surging stops. Also, check for a defective pressure switch.
  • B
    Bridget FullerAug 23, 2025
    What to do if Fimco LG-30-3N-TRL pump does not prime?
    • A
      Ashley HarrisAug 23, 2025
      If your Fimco Paint Sprayer pump isn't priming, try these checks: * Look for air leaks in the supply line. * Check for debris in the check valve assembly or a defective check valve. * Ensure the strainer/filter isn't clogged. * Inspect the pump housing for cracks. * Make sure your product supply isn't empty.
  • J
    Julia MorenoAug 28, 2025
    Why does the Fimco Paint Sprayer motor continue to run after the discharge is shut off?
    • D
      Dakota DixonAug 28, 2025
      If the motor of your Fimco Paint Sprayer continues to run after the discharge is shut off, consider these possibilities: * The product supply might be empty. * The bypass valve might be open (if equipped). * There could be low voltage or a leak in the discharge line. * The pressure switch might be defective. * The system may have leaks.
  • A
    Ashley HancockSep 2, 2025
    Why does the fuse keep blowing in my Fimco Paint Sprayer?
    • C
      Cole PerezSep 2, 2025
      A fuse blowing in your Fimco Paint Sprayer can be caused by: * Excessive voltage. * Improper adjustment of the pressure switch. * A damaged or defective wiring harness. * The half-moon & counterweight sticking. * A defective pressure switch.

Summary

General Information and Safety

Safety Warnings

User must read manual to reduce injury risk. Includes Cancer and Reproductive Harm warning.

Sprayer Assembly Steps

Boom Assembly Mounting

Testing and Operation

Testing the Sprayer

Test sprayer with plain water to check for leaks and proper function before chemical use.

Using the Boom Nozzles

Maintenance and Storage

Pump Troubleshooting

Motor Not Running

Check wiring, ON/OFF switch, pressure switch, fuse, and voltage.

Pump Not Priming

Inspect for air leaks, debris in check valve, clogged strainer, or pump housing cracks.

Low Pressure;Flow Issues

Check discharge lines for leaks/restrictions, nozzle orifices, strainer, and voltage.

Pulsating or Surging Flow

Adjust spray pattern, open bypass valve, or check pressure switch and line restrictions.

Motor Continues Running

Verify product supply, bypass valve closure, voltage, discharge leaks, or pressure switch.

Fuse Blowing

Investigate excessive voltage, improper pressure switch adjustment, or wiring issues.