The FINE 4019 PIXIE PLUS LED is a sophisticated lighting fixture designed for professional applications, offering a wide range of features for precise control and dynamic effects. This user manual provides comprehensive details on its technical specifications, operation, and maintenance.
Function Description:
The FINE 4019 PIXIE PLUS LED is a versatile moving head light that utilizes 40W 4-in-1 LEDs to produce a rich RGBW color system. It is capable of all-optical domain dimming with 65,536 grades of accuracy, ensuring smooth and precise light intensity control. The fixture boasts a fast strobe function ranging from 1-25Hz and comes with a variety of preset color macro functions (65) and effect macro functions (64), allowing for quick and easy creation of complex lighting scenes. Its motorized Pan and Tilt movements offer a wide range of motion, with fine control for accurate positioning. The fixture also features a zoom function, enabling adjustment of the spot angle from small to large, and a lenses rotation function for dynamic beam shaping.
Important Technical Specifications:
- Light Source: 40W 4-in-1 LEDs
- Input Voltage: 100-240V~50/60Hz
- Input Current: 9A
- Input Power: 900W
- Power Factor: >0.98
- Beam Angle: 4°~60°
- Initial Luminous Flux: Small angle: 5834.8 lm, Large angle: 12791 lm
- Efficiency: Small angle: 6.9 lm/W, Large angle: 15.14 lm/W
- Color System: RGBW 4 in 1
- Dimming: All-optical domain dimming, 65,536 grade dimming accuracy
- Strobe: Fast strobe 1-25Hz
- Pan Movement: 2.11°/step, Pan fine=0.008°
- Tilt Movement: 270°, Tilt=0.94°/step, Tilt fine=0.0037°
- Safety Protection: Over current, over voltage, and overheating protection
- Control Mode: DMX512/Wireless DMX (optional)
- Control Channels: 21/35/78/97 (selectable)
- Work Environment Temperature: 0°C~40°C
- Fixture Dimension: 400×378×500mm
- Package Dimension: 841×515.5×735.5mm (for 2pcs/flight case)
- Weight: Net weight: 20kg, Gross weight: 42kg (for 2pcs/flight case)
- IP Rate: IP20
- Included Items (per fixture): User manual (1), Warranty card (1), Female plug (1), Signal cable (1), Safety wire (1), Fuse (2).
Usage Features:
The FINE 4019 PIXIE PLUS LED offers extensive control options through its display panel and DMX connectivity.
- DMX Control: The fixture supports DMX512 and optional Wireless DMX. It provides multiple control channel modes (21, 35, 78, 97) to suit different levels of control complexity. DMX input and output are facilitated via 3-pin or 5-pin XLR connectors. A terminator (120Ω resistor) is recommended for the last fixture in a data link to prevent signal reflection and interference. For long-distance data transfer, a DMX512 signal amplifier may be necessary.
- Control Panel Operation: The fixture features an intuitive control panel with an LCD display, exit button, function (Enter) button, and a jog wheel.
- Jog Wheel: This multi-functional control allows users to navigate menus, select items, save values (single press), scroll pages, increase/decrease parameter values (rotate), and return to previous or main menus (long press).
- Main Menu: Provides access to settings such as IP address, feature settings, speed settings, and channel settings.
- Specification Setting: Allows configuration of Pan/Tilt invert, Pan/Tilt swap, DMX mode (Standard, RGB, RGBW, SHAP), Pan/Tilt speed (Fast, Normal, Slow), Pan/Tilt smooth, Gobo/Color speed, Dimmer curve (Gm10, GM15, Gm20, S), and Dimmer smooth.
- Manual Control: Enables direct adjustment of individual channel values for Red, Green, Blue, White, CTC, Color Macro, Strobe, Dimmer, Pan, Tilt, Function control, Reset, Zoom, Prism rotation, Shape Selection, Shape Speed, Shape Fade, Shape R, Shape G, Shape B, Shape W, Shape Dimmer, Background Dimmer, Shape Transition, Shape Offset, Shape Strobe, Background Strobe, and Background Selection.
- Calibration: Offers zero setting and calibration for Pan, Tilt, Zoom, and Prism rotation to correct deviations.
- DMX Values: Displays received DMX channel values (01-48).
- Password Protection: Allows setting a password to modify restrictions on usage times and verification codes when reloading default settings.
- Display Settings: Configures display brightness, display revert (on/off), and backlight shutdown time (60s default).
- Language: Supports Chinese and English menu display.
- Receive Mode: Selects between DMX512, Wireless DMX (WDMX), Ethernet (ENET), and Ethernet to DMX (EDMX) transmission modes.
- Personality Settings: Includes Universe setup for Art-Net Ethernet nodes, IP address configuration, and options to load/save user configurations (Config 1, Config 2) or reload/save default settings.
- Fixture Type: Displays the fixture type (F4019).
- Sleep Mode: Enables or disables sleep mode.
- Error Display: Enables or disables error display.
- Information: Provides inquiry for Power On Time, Lamp On Time, Dimming Time, CPU Board Temperature, CPU Board Version, Manufacturer ID, Device ID, FAN 1 Speed, FAN 2 Speed, P/T Driver Board Temperature, P/T Driver Board Version, LED Board Temperature, and LED Board Version.
- Sensor Monitor: Monitors the normal functioning of Pan, Tilt, Zoom, and Prism rotation sensors, indicating errors if detected.
- Reset All Systems: Allows users to reset the fixture to original settings or cancel the reset.
- Power Connection: The fixture uses a 100-240V~50/60Hz power supply and a 10A 6X30 fuse. It is crucial to connect the yellow/green wire to earth. The power supply connection is Type Y, meaning replacement of the cable or cord must be done by the manufacturer, service agent, or similarly qualified person.
- Safety Information: The manual emphasizes critical safety warnings, including risks of severe injury or death from electrical shock, fire hazards, burn hazards from hot surfaces, eye injury from direct bulb stare, and hand injury. It also highlights the importance of replacing damaged protective shields and maintaining a minimum distance of 0.5m from flammable materials. The fixture is designed for indoor use only and should not be actuated during operation.
Maintenance Features:
Routine maintenance is essential to ensure the longevity and optimal performance of the FINE 4019 PIXIE PLUS LED.
- General Cleaning: Excessive dust, smoke fluid, and particulate buildup can degrade performance and lead to overheating or damage, which is not covered by warranty. Always unplug the fixture before opening any covers.
- Optical Components Cleaning:
- Switch off the fixture and allow it to cool completely before opening the cover.
- Clean floats using a dust collector or compressed air.
- For granular debris, use cotton paper or cloth soaked with distilled water. Avoid wiping the surface directly; instead, blow away loose particles with pressure gas.
- For smoke and other residues, use cotton cloth or paper soaked with isopropyl alcohol. Commercial glass cleaner can be used, but any residues must be removed with distilled water. Clean with a slow circular motion from the center to the edge, then dry with a clean, soft, lint-free cloth or compressed air.
- Fan and Air Vents Cleaning: Remove dust from the fans and air vents using a soft brush, cotton paper, vacuum, or compressed air.
- Light Source Replacement: The light source is not recommended to be replaced by the user. Qualified maintenance personnel should perform this task to prevent damage or overheating deformation.