Never apply voltage to the inputs.
Temperature affects readings. Allow the CLM
33
to attain the
ambient temperature of the wire under test.
The sample length of user wires for the User Select Mode must be
5m in METER or 20ft in FEET mode.
The Listing label on the bottom case of the meter enables users to
make a short memo of each user wire for the User Select Mode.
Use a 9 volt alkaline battery only.
If the meter is on and inactivate for approximately 15 minutes, the
meter will automatically enter into Sleep mode and display “ ”.
Reactivate the meter by turning the selector to any position or
pressing any button.
Use the test leads that come with the meter only. Other leads will
not work.
Ensure that the test leads are clean and in good working order.
Use an abrasive pad similar to the one provided to ensure the
wire under test is clean and free of oxidation.
Ensure that the alligator clips are connected across the diameter
of the wire under test.
When measuring wire for insertion into conduit, add extra wire to
compensation for the accuracy of the meter. For example, 104m
of wire needed to run inside a piece of conduit that is 100m long.
(This would allow 2m on each end to attach the wire.) At
104m and
21°C, the cable length meter has an accuracy of ±1m.
In this case,
it would be safer to measure out 105m of wire.
This would ensure
that enough wire is available for the application.