9. Description of software operation
s:
• Measured from the receiverˈreceiving distance of remote control should 8mˈreceiving
ang
le60econe angle˗
• Discrepancy of temperature controlf1ć˗
• Discrepancy of time control5min/24h˗
• Discrepancy of indoor PG fan speed˖f10rpm˗
z˗
• PCB should conform to
RoHS.
9.2 Definition
•RT˖room temperature.
•IPT˖indoor coil temperatur
e.
•ST˖setting temperatureˈrange 1830ć
•OPT˖outdoor coil temperature.
• NTC data˖R25=5.0Kȍf1% B25/50=3470f
1%
9.3 Mode introduction
After running the unit by ON/OFF key or choose the auto running mode by remote control, it will fix its
running mode by judging room temperature (see below table):
Indoor temp.
Indoor temp.20
Running mode heating fan cooling
Note:
1. When Auto mode is selected, unit would check room temperature first and work with fixed mode
as
above accordingly. Every 6 minutes, unit would check room temperature again, running mode would
b
e changed according with update room temperatur
e.
If working mode is changed by remote control unit has 3 minutes delay protection for compressor
.
3.
Fan speed selection: For Dry mode, fan speed is fixed with low speed. For Cooling, Heating
and Fan
mode, fan would work with set speed.
4. Unit has protection function, including 3 minutes delay function, Anti-cold function before heating,
Over heating protection during heating function, Anti-frozen during cooling mode, E1,E2,E3,E4
protection.