minimum of 30 cm (12 in) from the side wall (see Diagram
5).
Put smoke alarm at both ends of a bedroom hallway or large
room if the hallway or room is more than 9.1 m (30 ft) long.
Install smoke alarms on slopped, peaked or cathedral
ceilings between 500 and 1500mm from the highest point
of the ceiling. Smoke alarms in rooms with ceiling slopes
greater than 1m in 8 m horizontally shall be located on the
high side of the room (See Diagram 6)