4.2.1 FILLING THE JACKET
WARNING! :
Do not open the tap level of the double jacket or the filler cap until the pressure in the
double jacket has been reduced to approximately atmospheric pressure.
WARNING! :
The water level in the jacket must be checked each time before lighting.
It is advisable to use softened water to fill the jacket!
− Open the level tap on the front of the appliance (fig.1).
− Unscrew the filling cap on the safety valve unit (fig.2).. The latter is on the right of the appliance surface (
− Fill with softened water .
− When water flows out of the level tap, close it and screw back on the safety unit cap.