INSTRUCTION MANUAL FOR INSTALLATION, MAINTENANCE AND
USE Rev−12
PMKIE−DIMU−GB−12
19
GB
INDIRECT TILTING PANS, ELECTRIC TYPE
ˆPMKIE100˜ ˆPMKIE150˜ ˆPMKIE200˜ ˆPMKIE300˜ ˆPMKIE500˜
4.2.1 FILLING THE JACKET
WARNING! :
Do not open the tap level of the double jacket or the filler cap until the pressure in the
double jacket has been reduced to approximately atmospheric pressure.
WARNING! :
The water level in the jacket must be checked each time before lighting.
It is advisable to use softened water to fill the jacket!
Open the level tap on the front of the appliance (fig.1).
Unscrew the filling cap on the safety valve unit (fig.2).. The latter is on the right of the appliance surface (
Fill with softened water .
When water flows out of the level tap, close it and screw back on the safety unit cap.