INDIRECT TILTING PANS, ELECTRIC TYPE
ˆPMKIE100˜ ˆPMKIE150˜ ˆPMKIE200˜ ˆPMKIE300˜ ˆPMKIE500˜
3.6 JACKET CLEANING (SERVICE TECHNICIAN)
Washing the jacket serves to prevent possible limestone deposits inside the jacketr and ensure the optimal
functioning of the pan.
Depending on the water hardness we recommend the following maintenance interval:
ANNUAL
If water hardness> 16 ° f (French degrees)
THREE-YEAR
If water hardness> 8 ° f <16 ° f (French degrees)
FIVE-YEAR
If water hardness> 4 ° f <8 ° f (French degrees)
1. Leave the pan to cool completely . Make sure that there is no pressure !.
2. Remove the jacket discharge cap (fully discharge jacket) and screw
the cap.
4. Remove the threaded cap from the
group filling jacket.
5. Slowly pour the descaling product (limescale) using a funnel to fill the racket.
Carefully follow the instructions on the descaling product used, both for the dilution
that for the time of action of the product.