6 INSTALLATION
6.1 INSTALLATION CODES AND STANDARDS
Electrical grounding must be provided in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA
C22.2, as applicable.
The electrical diagram is located on the inside of side panel of right hand console.
6.2 REQUIREMENTS FOR THE INSTALLATION SITE
The room in which the appliance is to operate must be well ventilated.
The appliance belongs to the installation class A1 (no direct connection of a chimney of flue exhaust system is
required), so it is very important for the environment in which it is installed to be well-aired and provided with all
the safety openings prescribed for its power.
VENTILATION
The appliance are only to be installed under a ventilation hood in a room which has provisions for
adequate make up air.
Information on the construction and installation of ventilating hoods may be obtained from the
standard for “Vapor Removal from Cooking Equipment”, NFPA No. 96 (latest edition), available
from the National Fire Protection Association, Batterymarch Park, Quincy, MA, USA, 02269.
The electrical isolating switch and the water shutoff valves must both be located near
to the appliance, within easy reach for the user.