CONNECTIONS
01
-
UDBRE.A_V1
-
DIMU
-
00
-
EN
27
7 CONNECTIONS
Attention: When the appliance is equipped with casters (optional), the appliance shall be
installed using a flexible conduit.
Adequate means must be provided to limit the moviment of the appliance without
depending on or transmitting stress to the electrical conduit.
The location where the restraining means may be attached to the appliance are the two
eyebolts positioned on the back of the appliance.
Utility connections must be made with flexible lines of sufficient length to allow the
equipment to be moved for cleaning of the equipment and adjacent area.
7.1 ELECTRICAL CONNECTION
During installation, observe the regulations provided by the local electricity company.
The appliance is supplied to operate according to the power supply indicated on
appliance's rating plate.
A separate fused disconnect switch must be supplied and installed. The appliance must be
electrically grounded by the installer.
The earthing system must be efficient.
The electric supply must match the power requirements specified on the appliance's rating
plate.
The copper wiring must be adequate to carry the required current at the rated voltage.
The connection point is indicated in the "PLANT CONNECTION"
Ensure main power is turned off before connecting wires.
The terminal board can be reached by unloosing the screws (on the back-side of the appliance) on the bracket
fastening the terminal board housing. The whole housing will come down and the terminal board will be easy
to reach.
Insert the cable through the cable gland. Carefully connect the conductors to the corresponding terminals. The
earth conductor must be longer than the other conductors, so as to disconnect last in the event of a strong pull
of the cable or break of the cable gland. Tighten the cable gland.