5. Connect the Coupling to Generator, then connect the Hose to both Generator and
Quick Connect Adapter. Make sure the Generator is turned OFF before connecting
the Hose to the Generator (Figure 7).
NG Inlet located
on the Generator
10ft NG Quick Connect
Hose Assembly
Quick Connect Adapter
House NG
Piping
Figure 7
To connect the Hose to the Quick Connect Adapter, pull back on the sleeve portion of the Adapter
and insert the male connector of the Hose into the socket (female) part of the Adapter. Release the
sleeve and continue pushing the Hose into the socket until the sleeve snaps into the locked position.
Connect other side of the Hose to the NG inlet connector located on the Generator.
6. Turn on gas supply.
7. Check all the connections and joints with ammonia free soapy water solution or leak
detection solution. Bubbles that appear to grow in size are the indication of a gas leak
(Figure 10).
English Customer Service: 1-844-FIRMAN1
04
Hose
Male Connector (Plug)
Quick Connect
Adapter
Pull Back
the Sleeve
Release the Sleeve and
Make Sure the Sleeve
Snaps into the Locked
Position.
Figure 8 Figure 9
Coupling
Pipe Nipple

Questions and Answers: