English Customer Service: 1-844-FIRMAN1Page
18
If a cover is used, do not install until unit has
cooled.
NOTE: Disconnect the LPG cylinder from the
generator during transportation.
WARNING
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or explosion
resulting in death, serious injury and/or property
damage.
DO NOT stop engine by moving choke control to
START” position.
Important: Always ensure that the fuel selector
switch is in the “OFF” position when the engine is
not in use.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section for
proper engine and fuel storage.
Indicator light - Battery Power Saving Mode
This generator is equipped with an electronic
module which consumes battery power. When the
fuel selector switch is turned to the “GAS” or “LPG
position, the indicator light will become RED up to
4 minutes(before goes off).
Starting the engine successfully during these 4
minutes will turn the indicator light GREEN.
Starting the engine unsuccessfully or not
attempting to start the engine at all during these 4
minutes will switch generator to Battery Power
Saving Mode in order to conserve and increase the
life of battery.
MUST HAVE SOLID RED INDICATOR LIGHT TO BE
ABLE TO START THE GENERATOR. THE GENERATOR
CANNOT BE STARTED DURING BATTERY POWER
SAVING MODE UNLESS THE FUEL SELECTOR
SWITCH IS TURNED TO THE OFFPOSITION AND
THEN TURNED BACK TO THE GAS OR LPG
POSITION.
Unwanted Shutdown:
The indicator light will start FLASHING for 4
minutes in the event of any unwanted shutdown
such as low oil, running out of fuel(gasoline or LPG),
or any other unwanted shutdown. This is a
reminder that the generator is switching to Battery
Power Saving Mode. The generator should be
checked for any unwanted shutdown.
The generator cannot be started during or after the
4 minutes of FLASHING mode unless the fuel
selector switch is turned to the "OFF" position and
then turned back to the “GAS” or “LPG” position.
This generator is equipped with an automatic
battery charging circuit and the battery will
receive a proper charge when the engine is
running to keep the battery charged.
Low Oil Shutdown
If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with
dipstick.
If oil level is between LOW and HIGH mark on
dipstick:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is
corrected.
If oil level is below LOW mark on dipstick:
1.Add oil to bring level to HIGH mark.
2.Restart engine and if the engine stops again a
low oil condition may still exist. DO NOT try to
restart the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is
corrected.