SPECIFICATIONS
AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
When operated above 7F(2C) there may be a decrease in power.
Maximum wattage and current are subject to and limited by such factors as fuel BTU content
ambient temperature, altitude, engine condition and etc. Maximum power decreases about
3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 1F(-12.2°C)
above 6F(16°C) ambient temperature.
Model
Rated AC Voltage
Phase
Power Factor
Voltage regulator
Alternator Type
Running Watts
Starting Watts
Engine
Engine Type
Displacement
Low Oil Shutdown
Ignition System
Starting System
Fuel
Capacity Fuel Tank
Lubricating Oil Capacity
Carburetor Type
Air Cleaner
P.T.O. shaft rotation
120V
P01202
1200
Capacitor
Single Phase
1
Single Cylinder, 4-Stroke OHV Air Cooled
80 cc
Breakless Ignition Type, Flywheel Magneto
Unleaded Automotive Gasoline
Recoil
1.7 Gallon
12.9 oz(0.38L)
Counter Clockwise (Facing P.T.O.)
Float
Brushless
Polyurethane Type
YES
1500
FIRMAN
Rated Fequency
60Hz
Oil Type
See “Add Engine Oil” Section
English Customer Service: 1-844-FIRMAN1
10
Total Harmonic Distortion(THD)
Standard
AC Grounding System
Neutral Bonded To Frame