P/N:312745450 Rev:01
OWNERS MANUAL
Read all safety precautions and instructions carefully
before operating equipment.
Ensure engine is stopped and level before performing
any maintenance or service.
IMPORTANT:
Record product information to reference when ordering parts or
obtaining warranty coverage.
Serial Number:
PORTABLE GENERATOR
MODEL NUMBER
P01201
Rev Level:01
DO NOT RETURN TO
STORE!
CALL US FIRST!
CUSTOMER HOTLINE
1-844-347-6261
FOR QUESTIONS OR SERVICE
INFORMATION
Purchase Date:

Questions and Answers

  • V
    Victoria LeeAug 2, 2025
    What to do if Firman Portable Generator engine shuts down when running?
    • S
      Scott FoxAug 2, 2025
      If your Firman Portable Generator shuts down while running, it could be due to: - Being out of fuel; in this case, fill the fuel tank. - A dirty air cleaner; clean or replace the air cleaner. - Low oil level; fill the crankcase to the proper level or place the generator on a level surface.
  • S
    Sandra Kerr DDSAug 7, 2025
    Why Firman P01201 engine lacks power?
    • E
      Emily SnyderAug 7, 2025
      If your Firman Portable Generator engine lacks power, consider the following: - The load might be too high. - The air filter could be dirty; replace it. - The fuel filter might be clogged or dirty; clean or replace it. - The spark arrester may be clogged; clean or replace it.
  • J
    Justin BentleyAug 12, 2025
    What to do if Firman Portable Generator engine runs good at no-load but “bogs down” when loads are connected?
    • L
      Luis KerrAug 12, 2025
      If your Firman Portable Generator runs well without a load but bogs down when loads are connected, consider these possibilities: - There may be a short circuit in a connected load; disconnect the shorted electrical load. - The fuel filter may be clogged or dirty; clean or replace it. - The generator may be overloaded. For the following issues, it's best to contact an authorized service facility: - Engine speed is too slow. - Shorted generator circuit.
  • A
    anndavidAug 17, 2025
    How to troubleshoot no AC output on Firman P01201 Portable Generator?
    • S
      sandovalmichelleAug 18, 2025
      If your Firman Portable Generator's engine is running, but there's no AC output, check these: - The circuit breaker might be open; reset it. - There might be a poor connection or a defective cord set; check and repair. - The connected device may be faulty; connect another device that is in good condition. If these steps don't resolve the issue, it could indicate a fault in the generator, and you should contact an authorized service facility.
  • L
    Laura RamirezAug 22, 2025
    What causes Firman P01201 engine to hunt or falter?
    • N
      Nicole MerrittAug 23, 2025
      If your Firman Portable Generator engine “hunts” or falters, it could be due to: - A clogged or dirty fuel filter; clean or replace the fuel filter. For the following issue, it's best to contact an authorized service facility: - The carburetor is running too rich or too lean.
  • D
    Deanna RobertsonOct 27, 2025
    Why Firman Portable Generator engine will not start?
    • D
      davismarkOct 27, 2025
      Your Firman Portable Generator might not start due to several reasons: - The engine switch may be set to the OFF position; set it to the ON position. - The fuel shutoff lever may be in the OFF position; move it to the ON position. - The oil level might be low; fill the crankcase to the proper level or place the generator on a level surface. - The air cleaner could be dirty; clean or replace it. - The generator may be out of fuel; fill the fuel tank. - The fuel may be stale; drain the tank and carburetor and fill with fresh fuel. - The spark plug wire may not be connected; connect it to the spark plug. - The spark plug may be bad; replace it. - There might be water in the fuel; drain the tank and carburetor and fill with fresh fuel. - The engine may be flooded; wait 5 minutes and try re-c...

Summary

Introduction and Safety Overview

Important Safety Information

Highlights critical safety information for generator operation and maintenance.

Safety Hazard Identification

Explains hazard levels (Danger, Warning, Caution) and common safety symbols.

Safety Precautions for Generator Use

Carbon Monoxide (CO) Hazard Awareness

Details the dangers of carbon monoxide exhaust and safe operating practices.

Chemical Exposure Warnings

Warns about chemicals in product components and exhaust, per California regulations.

Operating Safety Guidelines

Kickback, Fuel, and General Operating Safety

Covers starter kickback, fuel flammability, and general operation restrictions.

Marine Use Disclaimer and Electrical Shock Hazard

States the generator is not for marine use and warns about electrical shock risks.

Safe Operating Environment and Practices

Electrical Safety and Environmental Precautions

Advises on GFCI use, wet conditions, unauthorized operation, and exhaust hazards.

Operational Limits and Modifications

Warns against exceeding capacity, tampering with governor, and unauthorized modifications.

Generator Unpacking and Parts

Unpacking the Generator

Instructions for safely opening the carton and removing the generator and accessories.

Included Generator Parts

Lists the components included with the gasoline powered generator.

Shipping Support Removal

Essential Shipping Support Removal Steps

Provides instructions and cautions for removing shipping supports before operation.

Generator Controls and Features

Generator Component Identification

Identifies key external parts of the generator with numbered labels.

Control Panel Overview

Control Panel Functions and Components

Details the engine switch, receptacles, circuit breakers, and ground terminal.

Generator Specifications

Product Model and Performance Specifications

Lists technical details like model number, watts, voltage, engine type, and capacity.

Engine Oil Management

Engine Oil Type and Level Check

Guides on selecting oil type, checking level, and filling the engine oil.

Low Oil Shutdown Feature

Explains the engine's automatic shutdown mechanism due to low oil level.

Fueling the Generator

Fuel Requirements and Safety Precautions

Specifies fuel type, octane, and safety measures during fueling.

High Altitude Fueling Considerations

Discusses fuel octane requirements and performance adjustments for high altitudes.

Electrical System Connection

Connecting to Building Electrical Systems

Instructions for connecting the generator to a building's electrical system safely.

Generator Grounding Procedures

Details the importance and method for properly grounding the generator.

Generator Operation Guidelines

Generator Placement and Ventilation

Specifies safe locations and ventilation requirements for generator operation.

Protecting Electronics from Voltage Fluctuations

Advises on using surge suppressors to protect sensitive electronic equipment.

Starting the Generator

Pre-Start Checks and Setup

Outlines essential checks before starting the engine, including oil and fuel levels.

Generator Startup Procedure

Step-by-step instructions for safely starting the generator engine.

Load Connection and Shutdown

Connecting Electrical Loads to Generator

Guides on how to safely connect and manage electrical loads to the generator.

Generator Engine Shutdown Procedure

Details the correct steps for turning off the generator engine safely.

Avoiding Generator Overload

Safe Load Addition Strategy

Provides a method for adding electrical loads incrementally to prevent overloading.

Maintenance and Storage Schedule

Generator Maintenance Schedule

Outlines routine maintenance tasks based on operating hours or time intervals.

General Maintenance Recommendations

Offers general advice for maintaining the generator for performance and longevity.

Engine Maintenance Procedures

Engine Oil Change Procedure

Step-by-step guide for draining, filling, and checking engine oil.

Air Filter Cleaning and Maintenance

Instructions for cleaning and maintaining the air filter for optimal engine performance.

Spark Plug and Fuel System Care

Spark Plug Maintenance and Adjustment

Details procedures for inspecting, cleaning, gapping, and installing the spark plug.

Fuel Strainer Cleaning Procedure

Explains how to clean the fuel strainer to ensure proper fuel flow.

Muffler and Spark Arrester Inspection

Guides on inspecting the muffler and spark arrester for damage or blockage.

Generator Cleaning and Care

General Generator Cleaning Instructions

Provides guidance on cleaning the generator's exterior and ensuring proper ventilation.

Service and Storage Procedures

Infrequent Generator Service

Instructions for maintaining the generator when used infrequently to prevent starting issues.

Long Term Generator Storage

Detailed steps for preparing and storing the generator for extended periods.

Troubleshooting Generator Issues

Troubleshooting Engine Performance Problems

Addresses common engine issues like rough running, no output, or bogging down.

Troubleshooting Power and Shutdown Issues

Covers problems related to lack of power, engine hunting, or unexpected shutdowns.

Generator Parts Diagrams

P01201 Generator Assembly Diagram

Visual representation of the generator's main assembly with numbered parts.

Engine Parts Diagrams

152 F 80 cc Engine Component Diagram

Exploded view of the 80cc engine showing individual components.

Generator Parts Identification

P01201 Generator Parts List

A detailed list of generator parts with part numbers and quantities.

Engine Parts Identification

152 F 80 cc Engine Parts List

A comprehensive list of engine parts with part numbers and quantities.

Service Information and Parts Ordering

Contacting Firman Product Service Department

Contact details for product service, warranty information, and ordering parts.

Procedure for Ordering Replacement Parts

Steps and required information for ordering replacement parts for the generator.

Product Warranty Details

Warranty Qualifications and Coverage

Explains warranty registration, repair/replacement terms, and duration.

Warranty Exclusions and Limitations

Lists items and conditions not covered by the product warranty.

Emissions Control System Warranty

Owners Warranty Rights and Responsibilities

Outlines the owner's obligations and rights regarding the emissions warranty.

Emissions Control System Warranty Coverage

Details the scope and duration of the emissions control system warranty.

Covered Warranty Parts

Emissions Control System Parts List

Lists specific parts covered under the emissions control system warranty.

Emissions Warranty Limitations

Specifies what is not covered by the emissions control system warranty.

Firman P01201 Specifications

General IconGeneral
TypePortable Generator
Rated Wattage1200 Watts
Starting Wattage1500 Watts
Fuel TypeGasoline
Engine Displacement80cc
Tank Capacity1.7 gallons
Starting SystemRecoil
Noise Level68 dB
AC Output120V
DC Output12V, 8.3A
Engine Type4-Stroke OHV
Outlets1x 12V DC