OPERATION
12. Allow portable generator to run at no load for a few minutes to stabilize before plugging in
any electrical devices.
NOTICE If engine starts but fails to run, or if portable generator shuts down during operation,
check oil level. See Low Oil Shutdown section for more information.
8. For recoil start only-Pull the starter cord slowly until resistance is felt and then pull rapidly.
9. For electric start only-Flip the engine switch to the START (ll) position for a few seconds and then release.
10. Do not over-choke. As soon as engine starts and warms up, move the choke lever to the “RUN”
position.
11. Push and release the ''START'' button on the remote control. The generator will turn over for
3 to 5 seconds and start.
START
An engine warmup delay is programmed into the remote start cycle. After the generator is running,
there will be a delay of electrical output for 15 seconds.
If the engine fails to start within 3 to 5 seconds, the engine will attempt to start five additional times.
If the generator failed to start, the remote start indicator light will flash.
If the generator fails to start after a total of six attempts, the start button on the remote control must
be pushed again to begin another cycle of six start attempts.