OPERATION
10.
For recoil start only - Move the choke lever to the RUN position.
11.
For recoil start only - PULL-TO-RUN Pull the starter cord slowly until resistance if felt and pull
rapidly to run the portable generator.
If the engine fails to start in 1-2 pulls with choke in the RUN position, move choke lever to START
position and repeat the PULL-TO-PRIME step (9).
12.
For electric start only - Flip the engine switch to the START (ll) position for a few seconds and
then release.
13.
For electric start only - Move the choke lever to the RUN position.
14.
Allow portable generator to run at no load for a few minutes to stabilize before plugging in
any electrical devices.
NOTICE
If engine starts but fails to run, or if portable generator shuts down during operation,
check oil level. See
Low Oil Shutdown
section for more information.