9. Do not over-choke. As soon as engine starts and warms up, slowly move the choke lever to the
RUN position.
10. Allow portable generator to run at no load for a few minutes to stabilize before plugging in
any electrical devices.
NOTICE If engine starts but fails to run, or if portable generator shuts down during operation,
check oil level. See Low Oil Shutdown section for more information.
4. Starting the Generator on LPG
1. Before starting the generator, check for loose or missing parts and for any damage which may
have occurred during shipment. Ensure spark plug, muffler, fuel cap, and air cleaner are all in place.
2. Move portable generator outdoors to safe operating location at least 20 ft. (6 m) from any
occupied spaces.
3. Connect the LPG hose with regulator to both LPG cylinder and portable generator LPG/NG Hose
Connector (inlet).
LPG
4. Fully open the LPG cylinder knob.