SPECIFICATIONS
Model
WH03042
Starting Watts
3300(GASOLINE)/3000(LPG)
Running Watts 3000(GASOLIN E)/2700(LPG)
Rated AC Voltage 120V
Rated Feq uency 60Hz
Phase Single Phase
Voltage regulator
Digital
Power Factor
1
Total Harmonic Distortion(THD)
<3%
Alternator Type
Magneto lnducto r
Engine
FIRMAN
Engine Type
Single Cylinder, 4-Stroke OHV Air Cooled
Displacement
171 cc
Low Oil Shutdown
YES
Ignition System
Breakless Ignition Type, Flywheel Magneto
Starting System
Recoi 1/E lectric Sta rt
Fuel
Unleaded Automotive Gasoline/LPG
Capacity Fuel Tank
1.8 Gallon
Lubricating Oil Capacity
20.3 oz(0.6L)
Carburetor Type
Float
Air Cleaner
Polyurethane Type
P.T.O. shaft rotation Counter Clockwise (Facinq P.T.O.)
Oil Type
See "Add Enqine Oil" Section
AC Grounding System
Floating Neutral
AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
Your Firman Power Equipment product is designed and rated for continuous operation at
ambient temperatures up to 40°C (104°F). When your product is needed, your product may be
operated at temperatures ranging from -15°C (S°F) to 50°C (122°F) for short periods.
If the
product is exposed to temperatures outside this range during storage, it should be brought back
within this range before operation. In any event, the product must always be operated outdoors,
in a well-ventilated area and away from doors, windows and other vents.
When operated above 77°F(25°C) there may be a decrease in power.
Maximum wattage and current are subject to and Ii mited by sue h factors as fuel BTU content
ambient temperature, altitude, engine condition and etc. Maximum power decreases about
3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each l0°F(6°C)
above 60°F(l6°C) ambient temperature.