6. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned on.
7. Flip the engine switch to the "RUN" (I) position.
8. Push the battery power restore switch for about
3 seconds and then release.
9. Pull the choke lever out to the
"CHOKE" position.
1\1
~
10. Press and hold the engine switch in the "START"(II)
position for few seconds and release the switch to the
"RUN"(I) position.
-------
11 5
~
11. Push the choke button to the "RUN" position.
12. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
Connecling Electrical loads
This unit has been pretested and adjusted to
handle its full capacity. Before starting the
generator, disconnect all load. Apply load only
after generator is running. Voltage is regulated
via the engine speed adjusted at the factory for
correct output. Readjusting will void warranty.
A CAUTION
When applying a load, do not exceed the maximum
wattage rating of the generator when using one or
more receptacles. Also, do not exceed the amperage
rating of anyone receptacle.
Do not apply heavy electrical load during break-in
period (the first five hours of operations).
1.Let engine stabilize and warm up for a few
minutes after starting.
2.Ensure circuit breaker on control panel is in
on position.
3.Plug in and turn on the desired 120 Volt AC,
single phase, 60Hz electrical loads. It is
better to attach the item with largest load first.
NOH:
Connecting a generator to your electric utility
company's power lines or to another power
source may be against the law. In addition this
action, if done incorrectly, could damage your
generator and appliances and could cause
serious injury or even death to you or a utility
worker who may be working on nearby power
lines. If you plan to run a portable electric
generator during an outage, please notify your
electric utility company immediately and
remember to plug your appliances directly into
the generator. Do not plug the generator into
any electric outlet in your home. Doing so could
create a connection to the utility company
power lines. You are responsible for ensuring
that your generator's electricity does not feed
back into the electric utility power lines.
If the generator will be connected to a building
English
Page 23 Customer Service 1-844-FIRMAN1