6. Flip the engine switch to the "RUN"(I) position.
•©
~
7. Push the battery power restore switch for about
3 seconds and then release.
s1aning lhe Generator IEleclric s1ar1-LPGJ
NOTE: The generator will NOT start with LPG without
battery power or an appropriate connection.
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
2. Check oil level.
3. Connect the regulator(A) to both LPG cylinder
and generator. Connect the power cord(B) to the
8. Pull the choke lever out to the
"CHOKE" position. LPG regulator port. See "Connecting liquid
~
~-<J
Petroleum Gas(LPG/Propane) Cylinder" section
on page 13,14 and 15.
Use your fingers, slide the outer barrel back on
the LPG quick connect hose fitting. While the outer
barrel is in the back position, insert the LPG hose
(included) into the inlet and release the outer barrel.
The barrel will automatically return and lock the
9. Press and hold the engine switch in the
"START'(II) hose in the inlet
position for few seconds and release the switch to the
"RUN"(I) position.
II (D
~
10. Push the choke button to the "RUN" position.
11. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
NOTE: The gasoline valve is OPEN, when the fuel
selector switch is in "GAS"position(4:30 o'clock).
To close this valve, turn the slector switch to the
"LPG" position (1.30 o'clock).
------------------
4. Fully open the LPG cylinder knob.
5. Tum the fuel selector switch to "LPG" positbn(130 o'clock).