Remove the cap/plug and attach the quick
connect fitting
C to the quick connect in let
located on the control panel.
Attach the LPG regulator solenoid plug B to
the LPG regulator solenoid port located on
the control panel.
Remove the safety cap/plug from the cylinder
valve and attach the LPG regulator assembly
D to the LPG cylinder.
NOTE:
Tighten the nut by hand clock wise to a positive
stop.
Do not use a wrench to tighten.
Use of wrench may damage quick closing coupling
nut and result in a hazardous condition.
Don ot use tape or any type sealant to seal the
LPG hose connections.
You must use the supplied regulator/hose
assembly for safe operation.
Always position the cylinder so the connection
between the valve and the regulator won't cause
bends or kinks in the hose.
Spray a soapy water solution (one part liquid
detergent and one part water) to check all
connections for leaks before attempting to
use generator. Slowly open the cylinder valve.
A leak exists if bubbles appear or grow larger
in size ornumber. This must be corrected before
using the generator. Contact your local
Authorized Service Facility for assistance. Do
not attempt to make repairs yourself.
Do not check for leaks with a lighted match orflame.
Do not light or smoke cigarettes.
Check the fuel system periodically for leaks
or signs of dam ages.
English Page 15 Customer Service: 1-844-F IRMAN 1