CMX is t
he
Solution
https://
install.myfirstech.com
CMX
Master
Guide
Copyright 2020 Fi rste ch, LLC. “Hello, my name is Inigo Montoya....” Page
31
Option group #2
#2 Feature
Option Setting
Default(I) Option (II) Option (III) Option (IV)
2-1 Tach Threshold
Optimal Tach
Threshold
Previous Tach Method
2-2 Turbo Timer mode. Off 2 Min 1Min 4 Min
2-3 Diesel wait to start
Wait to start
input Wire
3~99 sec (12sec Default) 7 sec GM Ignition Delay
2-4 Trigger Start Off Single Pulse Double Pulse Triple Pulse
2-5
Cold or Hot Start
with Thermistor
Assembly
Off Cold start only Hot start only Cold and Hot start
2-6
Timer Start, or,
Minimum Interval
Between Cold Starts
3 Hour (4-
minute
runtime,
double for
Diesel)
2 Hour Repeat with Cold
Starting
of 2-8 (Runtime 2-7)
Reserved
(Runtime 2-7)
24 Hour Repeat with Cold
Starting of 2-8 (Runtime 2-7)
2-7
Remote Start
Runtime
15 Min 25 Min 45 Min
PROG. 3 ~ 45 mins
3 min (default)
2-8
Temperature of
Cold Starting
-10°C / 14°F -20°C / -4°F -5°C / 23°F
PROG. -30°C ~ 0°C / -22°F ~
32°F (-15°C / 5°F default)
2-9
Temperature of Hot
Starting
25°C / 77°F 30°C / 86°F 35°C / 95°F
PROG. 20°C ~ 66°C / 68°F ~
150°F (40°C / 104°F default)
2-10 Engine Sensing Tach Alternator
No Connection
(Voltage sensing, Automatic
Transmission only)
Assumed Running
PROG. 1~6 second output
(3 second default)
2-11 Advanced Tachless Off On
2-12 Min. Crank Time Standard +0.2 Seconds to Crank Time +0.6 Sec to Crank Time Standard – MIN(0.2sec)
2-13 Timer Mode Off On On w/ Alert Alert Only
2-14
Reservation "Enter
with":
(Manual
transmission)
Off Parking brake is set
Parking brake set + Hold
start button for 2.5 sec
Parking brake: set →
Release → (within 7
seconds) set
2-15
Reservation "set
with": (Manual
transmission)
last door
closed (locks
before shut
down)
Last door closed + Lock
command
10 Seconds After the Last
Door is Closed or Lock
Command
Last door is closed (Locks
after shut down)
2-16
Force Shutdown
after Remote Start
Off W/ Door Open W/ Unlock Command