1-14 FT- RFID Function: This feature covers the RFID unlock options. (Please refer to the FT-RFID
section of this manual for specific operation instructions and antenna mounting locations)
FO1 - Unlock “unlock once armed” (default): (The CMX must be in an armed state for this option
to function) This option will enable the FT-RFID proximity unlock/disarm feature after activating with a
Firstech RFID enhanced remote. (Refer to the FT-RFID section of this manual for specific operating
instructions). The CMX will be ready to send the disarm/unlock command 12-15 seconds after the
system has been armed using a Firstech remote or accessory (RPS, Drone, OEM remote input).
Approximately 12 seconds after armed, the system will look for the RFID enhanced remote and
disarm/unlock once the remote enters the proximity field.
FO2 - FTX Unlock “always unlock”: This option will enable the FT-RFID proximity unlock feature
after activating with a Firstech RFID enhanced remote. The CMX will always send the unlock/disarm
output when the remote enters/re-enters the proximity field regardless of the current state of the CMX.
(i.e. armed/locked-disarmed/unlocked). Once the remote leaves the proximity field, it will be set to send
the unlock/disarm output as soon as it enters/re-enters. Note: because the ANT-2WSF antenna is always
searching for the remote, it will produce more current draw than the standard RFID unlock option 3.
FO3 – Off: No RFID functions are available by default.
1-15 Trunk Output Timing: This feature determines the length of output time for the (+) or (-) analog trunk
release wire.
FO1 - 1 Second: (default) Will provide a 250mA (-) negative output for 1 second on any POC that is
programmed for trunk release or setting 28.
FO2 - 2 Seconds: FO1- 1 Second: (default) will provide a 250mA (-) negative output for 2 seconds on
any POC that is programmed for trunk release or setting 28.
FO3 - 3 Seconds: FO1- 1 Second: (default) will provide a 250mA (-) negative output for 3 seconds on
any POC that is programmed for trunk release or setting 28.
FO4 - 4 Seconds: FO1- 1 Second: (default) will provide a 250mA (-) negative output for 4 seconds on
any POC that is programmed for trunk release or setting 28.
1-16 Siren/Horn mute control: this feature allows the installer to enable or disable the siren/horn mute control.
The mute feature will silence the siren or horn during arm, disarm, and start from the Firstech remote.
FO1 - Disabled: (default) will not allow for the Firstech remote or Drone Mobile to mute the siren or
horn output.
FO2 - Enabled: this option will allow the end user to activate or deactivate the arm/disarm chirps using
a Firstech 4/5 button remote or Drone Mobile. NOTE: once “Mute” feature is enabled the “Pre-
Warn” output triggered from any additional alarm sensors will be muted/silenced as well.
FO3 – Silent ALARM: This option will allow the user to activate or deactivate the arm/disarm/pre-warn
chirps using a Firstech 4/5 button remote or Drone Mobile. In this mode the alarm once sounded will be
“silent” with no visible or audible notifications from the vehicle. There will be notifications sent to the
Drone Mobile or 2Way LCD remotes that may be in range. This will allow the user to be notified of the
alarm sounding without alerting anyone around the vehicle.