Copyright 2014 Firstech, LLC. Page 39
CM7000 Master Guide
Alarm and Starter System
techfeed.compustar.com
FO2 - On: (CM7200)/FO2- off (CM7000) Depending on the Control Module this option will enable
or disable the security features.
3-07 Siren Duration: this feature changes the duration of the siren during full alarm.
FO1 - 30 seconds: this option will provide 30 seconds of output (+) on the siren wire (brown CN5)
during full alarm.
FO2 - 60 seconds: this option will provide 60 seconds of output (+) on the siren wire (brown CN5)
during full alarm.
FO3 - 120 seconds: this option will provide 120 seconds of output (+) on the siren wire (brown
CN5) during full alarm.
FO4 - Chirps for 20 seconds: this option will provide 20 seconds of pulsed output (+) on the
siren wire (brown CN5) during full alarm.
3-08 Horn output: This feature controls the horn output behavior during Arm, Disarm, and Remote Start.
(POC setting #8)
FO1 - On double lock only: (default) this option is design to simulate a factory keyless entry
system by providing a horn output pulse (based on the option selection of feature 3-02) each time the
lock command is sent a second time within 8 seconds of the first lock command.
FO2 - On lock and Unlock only: this option will provide a horn output pulse (based on the
option selection of feature 3-02) with each lock or unlock confirmation.
FO3 - On lock, Unlock, and Start: this option will provide a horn output pulse (based on the
option selection of feature 3-02) with each lock, unlock, remote start command and remote started
confirmation.
FO4 - On double lock and Start: this option is design to simulate a factory keyless entry system
by providing a horn output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first. In addition it will provide a horn output
pulse with remote start command and remote started confirmation.
3-09 Siren output: This feature controls the siren (+) output behavior during Arm, Disarm, and Remote
Start.
FO1 - On lock, Unlock, and Start: (default) this option will provide a (+) siren output pulse
(based on the option selection of feature 3-02) with each lock, unlock, remote start command and
remote started confirmation.
FO2 - On double lock only: This option is design to simulate a factory keyless entry system by
providing a (+) siren output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first lock command.
FO3 - On lock and Unlock only: this option will provide a (+) siren output pulse (based on the
option selection of feature 3-02) with each lock or unlock confirmation.
FO4 - On double lock and Start: this option is design to simulate a factory keyless entry system
by providing a (+) siren output pulse (based on the option selection of feature 3-02) each time the
lock command is sent a second time within 8 seconds of the first. In addition it will provide a (+) siren
output pulse with remote start command and remote started confirmation.