FO4 - On double lock and Start: this option is designed to simulate a factory keyless entry system by
providing a (+) siren output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first. In addition, it will provide a (+) siren output
pulse with remote start command and remote started confirmation.
3-10 Valet Mode: This feature will change the enter/exit valet mode procedure based on the option
selected.
FO1 - Key 5 times with Foot Brake Trigger or Remote (Lock + Trunk) while Ignition is on: This
option allows the user to enter valet mode using either method described. Note: the user may exit valet
mode with their Firstech remote (please check users guide for each remote for valet mode exit
procedure), or with the key to ignition or “on” position
and press the foot brake 10 times within 10 seconds.
FO2 - Key 5 times with Foot Brake Trigger or Remote (Lock + Trunk): This option allows the user to
enter valet mode using either method described. Note: the user may exit valet mode with their Firstech
remote (please check users guide for each remote for valet mode exit procedure), or with the key to
ignition or “on” position and press the foot brake 10 times within 10 seconds.
3-13 Defrost output Temperature Control: This feature will determine the temperature at which the CM900
will provide an output on any POC programmed with setting 17 or 21 (defrost and defrost 2).
FO1 Standard (activate with every start): (Default) this option will provide an output (length of
output based on feature 3-13 option settings) on any POC programmed with setting 17 (defrost) or 21
(defrost 2) every time with remote start confirmation.
FO2 - 32°F: (thermistor required) this option will provide an output on any POC programmed with
setting 17 (defrost) or 21 (defrost 2) with remote start confirmation on. This will happen if the temp
reading is at or below 32°F. (Length of output based on feature 3-13 option settings)
FO3 - 42°F (default) PROGRAMMABLE 0°C/32°F ~ 13°C/55°F: (thermistor required) this option will
provide an output on any POC programmed with setting 17 (defrost) or 21 (defrost 2) with remote start
confirmation on. This will happen if the temp reading is at or below 42°F (default temp) but can be
programmed up to 55°F (using the OP500 programmer with software v.30 or newer)
(Length of output for POC setting 17, based on feature 3-13 option settings)
FO4 AUX 1: This option will allow the user to activate/deactivate the Defrost outputs using the AUX
1 function from any Firstech remote or DroneMobile. NOTE: This feature does not use an AUX output
3-14 Defrost output Timing: This feature controls the output timing of POC setting 17, defrost. Note: POC
setting 21 defrost 2 is has a fixed pulsed output and is NOT affected by this feature.
FO1 - 500mS Pulse: This option will provide a 500 Millisecond pulsed output on any POC
programmed with setting 17 (Defrost) with timing based off feature 3-12 option setting.
FO2 - 3 minute latched: This option will provide a 3-minute latched output on any POC
programmed with setting 17 (Defrost) with timing based off feature 3-12 option setting. (This would be
good for any rear-view mirror defrost that may need a short-latched output time.)
FO3 - 7 minute latched: This option will provide a 7-minute latched output on any POC
programmed with setting 17 (Defrost) with timing based off feature 3-12 option settings. (This
would be good for many front, rear, or rear-view mirror defrost functions that may need a longer
latched output time.)