1.0 Functions and Features
• Optical power test
• Wave ID — Auto wavelength identication & switching
• Frequency ID — Auto frequency identication
• 1000 records storage or download via USB cable
• USB communication port uploaded saves test results to PC
• Reference power level can be set up and stored
• Auto-o function
FIS E-Series Power Meter with Data
Saving
1
Remark: Battery operating time is based on the condition of the power
o the backlight. If power on the backlight continuously,
the operation time will be shorter.
2.0 Specications
Calibration Wavelength (nm)
850/1300/1310/1490
/1550/1625
Detector type InGaAs
Measurement Range (dBm) -70 ~ +6 -50 ~ +26
Uncertainty (dB) ±0.15 (3.5%)
linearity (dB) ±0.02
Display resolution(dB) 0.01
Frequency ID (Hz) 270, 1K, 2K
Date Storage Capacity 1000
Communication Port USB
Standard Connector SC/FC /2.5mm universal
Alkaline battery 3*AA, 1.5V
Power Adapter (V) 8.4
Battery Operating time (h) 200 without backlight
Operation Temperature (°C) -10 ~ +60
Storage Temperature (°C) -25 ~ +70
Dimension(mm) 200*90*50
Weight(g) 285