EasyManua.ls Logo

FIS E Series - FIS E-Series Power Meter Functions and Features; FIS E-Series Power Meter Specifications

Default Icon
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.0 Functions and Features
Optical power test
Wave ID — Auto wavelength identication & switching
Frequency ID — Auto frequency identication
1000 records storage or download via USB cable
USB communication port uploaded saves test results to PC
Reference power level can be set up and stored
Auto-o function
FIS E-Series Power Meter with Data
Saving
1
Remark: Battery operating time is based on the condition of the power
o the backlight. If power on the backlight continuously,
the operation time will be shorter.
2.0 Specications
Calibration Wavelength (nm)
850/1300/1310/1490
/1550/1625
Detector type InGaAs
Measurement Range (dBm) -70 ~ +6 -50 ~ +26
Uncertainty (dB) ±0.15 (3.5%)
linearity (dB) ±0.02
Display resolution(dB) 0.01
Frequency ID (Hz) 270, 1K, 2K
Date Storage Capacity 1000
Communication Port USB
Standard Connector SC/FC /2.5mm universal
Alkaline battery 3*AA, 1.5V
Power Adapter (V) 8.4
Battery Operating time (h) 200 without backlight
Operation Temperature (°C) -10 ~ +60
Storage Temperature (°C) -25 ~ +70
Dimension(mm) 200*90*50
Weight(g) 285