5.3 Auto reignition
The ignition box will sense when a flame has gone out (when a burner knob is in the ON
position) and try to reignite the flame. All the electrodes will spark during reignition.
During reignition the ignition box allows a period of approximately five seconds for the burner to
light. If a flame is not sensed in this period a fault condition will occur.
5.4 Fault conditions
There are two fault conditions that will result with the red LEDs flashing. The faults can be
distinguished by the speed at which the LEDs flash. The fault conditions are:
the burner has failed to light within a five second period during normal use or while trying to
auto reignite. (slow pulse flash)
there has been an interruption to the power supply during use. (rapid pulse flash)
In both fault conditions all the controls must be reset to the OFF position for the fault to be
cleared.