EasyManua.ls Logo

Fisher & Paykel DD24DC - Page 38

Fisher & Paykel DD24DC
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Fault codes
Fault codes Possible causes What to do
U1
Fill fault due to...
...water supply not
being turned on.
OR
...spray arm not being
fitted correctly.
Check if there is water in the
DishDrawer and follow the relevant
steps below.
If there is no water in the DishDrawer:
1
Turn on the water supply to the
DishDrawer.
2
Plug the DishDrawer back in or turn
it on at the power supply.
If there is water in the DishDrawer:
1
Plug the DishDrawer back in or turn
it on at the power supply.
2
Press the button and wait for 30
seconds.
3
Press the / button. The
DishDrawer will automatically drain
(approx. 2 minutes). You may need to
repeat steps 2 and 3 again.
4
When the DishDrawer is empty,
check that the spray arm is correctly
fitted and can rotate freely. See ‘User
maintenance instructions’.
U4
Fault in the other
drawer preventing the
use of this drawer.
Check other drawer, attend to fault code
on that drawer.

Other manuals for Fisher & Paykel DD24DC