- 28 -
U2
The tub drawer has been
sensed as open during
the cycle or the exhaust
valve is open circuit.
Is the drawer
open?
Shut the drawer.
Check the
microswitch is
working in
diagnostics.
Check the
mechanical
operation of the
the slides.
Replace the
microswitch.
Yes
No
OK Not OK
Note: Tub home microswitch is located on the rear
of the left slide runner and is connected in series with
the exhaust valve.
Test the exhaust
valve for an open
circuit.
Adjust the slides.
OK Not OK