EasyManua.ls Logo

Fisher & Paykel OR36S - Gas Conversion; Adjusting the Cooktop Burner Minimums

Fisher & Paykel OR36S
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
Adjusting the cooktop burner minimums
When switching from one type of gas to another, the minimum flow rate
must also be correct:
z
The flame should not go out even when passing suddenly from
maximum to minimum flame.
To regulate the flame follow these instructions:
Semi-rapid burner (
A
)
z
Light the burner
z
Set the gas valve to position (minimum rate)
z
Remove the dial.
z
With a thin screwdriver, turn the regulation screw inside the tap rod
until adjustment is correct.
Inside crown of DUAL burner (
B
)
z
Light the dual burner
z
Set the gas valve to position (minimum rate of inner crown)
z
Remove the dial
z
With a thin screwdriver, turn the regulation screw until adjustment is correct.
z
The screw is accessible via a hole in the microswitch.
Outside crown of DUAL burner (
C
)
z
Light the dual burner
z
Set the gas valve to position
(minimum rate of outer crown and maximum rate of inner crown).
z
Remove the dial
z
With a thin screwdriver, turn the regulation screw inside the tap rod
until adjustment is correct.
For LP/PROPANE gas, tighten the adjustmentacrews completely.
A Regulation screw (triple ring and semi-rapid burner)
B Regulation screw (inner crown of dual burner)
C Regulation screw (outer crown of dual burner)
GAS CONVERSION
Regulation
screws
A
Regulation
screws
C
B
Regulation
screws