Product Features
Page 32
with a preset temperature of 24°C.
The unit exits forced operation when it receives the
following signals:
Switch on
Switch off
Timer on
Timer off
Sleep mode
Follow me
Changes in:
mode
fan speed
setting temperature
Forced defrosting mode:
Press AUTO/COOL button continuously for 5s
under forced cooling mode to enter this mode.
Indoor fan will stop, defrosting lamp will light on.
Quit this mode and turn off the unit when:
quit normal defrosting
turn off by RC
Press AUTO/COOL button continuously for 5s
again
1.10 Timer function
Timing range is 24 hours.
Timer on. The machine will turn on automatically
when reaching the setting time.
Timer off. The machine will turn off automatically
when reaching the setting time.
Timer on/off. The machine will turn on automatically
when reaching the setting “on” time, and then turn
off automatically when reaching the setting “off”
time.
Timer off/on. The machine will turn off automatically
when reaching the setting “off” time, and then turn
on automatically when reaching the setting “on” time.
The timer function will not change the AC current
operation mode. Suppose AC is off now, it will not
start up firstly after setting the “timer off” function.
And when reaching the setting time, the timer LED
will be off and the AC running mode has not been
changed.
The setting time is relative time.
The AC will quit the timer function when it has
malfunction
1.11 Sleep function
The sleep function is available in cooling, heating, or
auto mode.
The operational process for sleep mode is as follows:
When cooling, the temperature rises 1°C (to not
higher than 30°C) every hour. After 2 hours, the
temperature stops rising and the indoor fan is fixed
at low speed.
When heating, the temperature decreases 1°C(to
not lower than 16°C) every hour. After 2 hours, the
temperature stops decreasing and the indoor fan is
fixed at low speed. Anti-cold wind function takes
priority.
The operating time for sleep mode is 8 hours, after
which, the unit exits this mode.
The timer setting is available in this mode.
1.12 Follow me
If you press “Follow Me” on the remote, the indoor
unit will beep. This indicates the follow me function is
active.
Once active, the remote control will send a signal
every 3 minutes, with no beeps. The unit automatically
sets the temperature according to the measurements
from the remote control.
The unit will only change modes if the information
from the remote control makes it necessary, not from
the unit’s temperature setting.
If the unit does not receive a signal for 7 minutes or
you press “Follow Me,” the function turns off. The
unit regulates temperature based on its own sensor
and settings.
1.13 Auto-Restart function
The indoor unit has an auto-restart module that
allows the unit to restart automatically. The module
automatically stores the current settings and, in the
case of a sudden power failure, will restore those
setting automatically within 3 minutes after power
returns.
If there is a power failure while the unit is running, the
compressor starts 3 minutes after the unit restarts. If
the unit was already off before the power failure, the
unit stands by.
1.14 8°C Heating
In heating mode, the temperature can be set to as low

Questions and Answers: