The Specification of Power
Indoor Units 17
8. The Specification of Power
36000 Btu/h
INDOOR UNIT
POWER
Frequency and
Voltage
220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz
POWER WIRING
(mm
2
)
CIRCUIT BREAKER
/ Fuse (A)
15/10 15/10 15/10 15/10
OUTDOOR UNIT
POWER
Frequency and
Voltage
220-240V, 50Hz 220-240V, 50Hz 380-420V, 50Hz
POWER WIRING
(mm2)
CIRCUIT BREAKER
/ Fuse (A)
Indoor/Outdoor Connecting Wiring
(Weak Electric Signal) (mm
2
)
2×0.2 (shielded)
Indoor/Outdoor Connecting Wiring
(Strong Electric Signal) (mm
2
)
INDOOR UNIT
POWER
Frequency and
Voltage
Power Wiring
(mm
2
)
Circuit Breaker/Fuse
(A)
OUTDOOR UNIT
POWER
Frequency and
Voltage
Power Wiring
(mm
2
)
Circuit Breaker/Fuse
(A)
Indoor/Outdoor Connecting Wiring
(Weak Electric Signal) (mm
2
)
Indoor/Outdoor Connecting Wiring
(Strong Electric Signal) (mm
2
)
30000 Btu/h
24000 Btu/h
Phase
1-phase
3-phase
3-phase
48000 Btu/h
1-phase
1-phase
1-phase
1-phase
1-phase
Phase
380-420V, 50Hz
3x2,5
3x4,0
5x2,5
5x2,5
3x1,5
3x1,5
3x1,5
3x1,5
30/20
30/25
3x 20/16
3x 20/16
2×0.2 (shielded)
2×0.2 (shielded)
2×0.2 (shielded)
Model
60000 Btu/h
Model
1-phase
Phase
3-phase
Phase
380-420V, 50Hz
380-420V, 50Hz
2×0.2 (shielded)
3x1,5
5x2,5
3x 30/20
15/10