Lit. No. 41298, Rev. 01 February 15, 2019
66
TROUBLESHOOTING
The quill in the valve manifold adjusts the blade
drop speed.
1. Lower the blade to the ground before making
adjustment.
2. Turn the quill IN (clockwise) to decrease drop
speed. Turn the quill OUT (counterclockwise)
to increase drop speed.
BLADE DROP SPEED ADJUSTMENT
WARNING
Keep 8' clear of the blade when it is being
raised, lowered, or angled. Do not stand
between the vehicle and blade or directly
in front of blade. If the blade hits or drops
on you, you could be seriously injured.
Quill
Fluid Level
NOTE: Remove fi ll plug slowly to relieve and
pressure in reservoir.
With Minute Mount
®
2 system attached to the
vehicle, activate control and lower the blade
to the ground. Turn control OFF. Remove the
fi ller/breather plug.
Fill reservoir to within 2-1/2" from the top of the fi ll
hole and replace fi ll plug.
For hydraulic fl uid type and fi lling instructions, see
Hydraulic System, Annual Fluid Change, in the
Maintenance section of the Owner's Manual.
CAUTION
Do not mix different kinds of hydraulic
fl uid. Some fl uids are not compatible and
may cause performance problems and
product damage