EasyManua.ls Logo

Fisher HT Series - Universal Security Code Clearing; Master Control Security Clearing Procedure

Fisher HT Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lit. No. 41298, Rev. 01 February 15, 2019
27
AIS
LOWER
ON/OFFFLOAT
Align the plate so that
only the LOWER button
on the keypad is exposed.
LOWER Button
Master Control
Plate
Master Control
Plate aligned
on the keypad.
Position the
Master Control Plate
over the keypad.
LOWER Button
Master Control
Plate
Keypad
UNIVERSAL CLEAR SECURITY
Perform the following steps to unlock and clear
an established security code, without using the
original control that was used to establish the code.
This procedure should be used to reset the module
if the security code is unknown.
WARNING
To prevent accidental movement of the
blade, always push the ON/OFF button
to switch the control OFF whenever
the snowplow is not in use. The power
indicator light will turn OFF.
HAND-HELD MASTER CONTROL FOR THE SECURITY GUARD™ SNOWPLOW ANTI-THEFT SYSTEM
IMPORTANT: The following steps must be
performed using the Distributor Master
Control (PN 48800). Only the Distributor Master
Control can clear an established code within
a snowplow module without using the original
control used to establish the code.
1. Turn the vehicle ignition to the "OFF" position.
2. With the control power OFF, using the tool that
was included in the Distributor Master Control
box, place the tool over the keypad and push
down on the plate.
NOTE: The only button that should be exposed
is the LOWER button. All other buttons should
be engaged and pressed down.
3. While pushing down on the tool engaging all
functions except LOWER, turn the ignition ON.
4. Upon turning the ignition to the "ON" position,
the module has been reset, and there is no
security code associated with the snowplow.

Other manuals for Fisher HT Series