IF HEATER FAILS TO START:
1. Press manual reset button at rear of burner. (Red button)
2. Check fuel level gauge for sufficient amount of fuel.
3. Make sure there are no air blocks in fuel lines or filter. Bleed lines if
required.
4. Ensure power supply plug is connected properly.
5. Check for dirty fuel filter or blocked fuel supply line.
6. Check burner nozzle assembly.
7. Make sure the burner control box does not need to be reset.
NOTE: IF THE BURNER HAS BEEN RESET SEVERAL TIMES THERE
MAY BE AN ACCUMULATION OF FUEL IN THE CHAMBER! DO NOT
CONTINUE TO TRY AND START THE HEATER!
DRAIN FUEL FROM HEAT EXCHANGER USING DRAIN HOLE AT FRONT
OF HEAT EXCHANGER FOR 15-20 MINUTES BEFORE ATTEMPTING TO
RELIGHT. LET REMAINING EXCESS FUEL BURN OFF BEFORE
CHECKING COMBUSTION OF UNIT.
SAFE OPERATION PRECAUTIONS:
1. Do not fill fuel tank while heater is operation.
2. Do not attempt to start heater if excess oil remains in the heat
exchanger.
3. Use switch to shut down the heater. Do not try to shut down the heater
by unplugging the electrical cord.
4. Do not plug anything other that the thermostat into the “Thermostat”
plug.
5. Do not use any fuel other that those listed on rating plate.
6. Before removing any guards or performing any maintenance, be sure
that the main power supply is disconnected.