APPLIANCE DATA
Main injector (1 off) Stereomatic Elbow size 76
Pilot Type. Copreci Single Flame 21100 / 161
Max. Gross Heat Input : 6.9 kW
Min. Gross Heat Input : 2.5 kW
Cold Pressure : 20.0 +/- 1.0 mbar (8.0 +/- 0.4 in w.g.)
Ignition : Rotary piezo, integral to gas valve
Electrode Spark Gap : 4.0 mm
Weight (Packed) : 20 kg
Firebox Dimensions (with case fitted)
Width: 715mm
Height: 620mm
Depth: 210mm
Height to top of the flue spigot : 525mm (with feet fitted)
Gas Connection : 8mm compression
(Supplied with fire)