Page 10
Master Programming Mode Chart
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
Master Programming Options
Abbreviation Parameter Option
Abbreviation
Options
DF Display Format
GAL Gallons
Ltr Liters
Cu Cubic Meters
VT Valve Type
St1b Standard Downflow/Upflow Single Backwash (Not Used)
St2b Standard Downflow/Upflow Double Backwash
(7000 Default)
Fltr Filter (7000 Default)
UFbF Upflow Brine First (Not Used)
8500 TwinFlo100SXT (Not Used)
Othr Other (Not Used)
dFFF Downflow Fill First (Fixed Fill)
IF Air Injected Oxidizer, AIO Valve Only.
CT Control Type
Fd Meter (Flow) Delayed
FI Meter (Flow) Immediate
tc Time Clock
dAY Day of Week
NT Number of Tanks
1 Single Tank System
2 Two Tank System (Not Used)
TS Tank in Service
U1 Tank 1 in Service
U2 Tank 2 in Service (Not Shown)
C Unit Capacity Unit Capacity (Grains)
H
Feedwater
Hardness
Hardness of Inlet Water
RS Reserve Selection SF Percentage Safety Factor
rc Fixed Reserve Capacity
SF Safety Factor
Percentage of the system capacity to be used as a re-
serve
RC
Fixed Reserve
Capacity
Fixed volume to be used as a reserve
DO Day Override The system’s day override setting
RT Regen Time The time of day the system will regenerate
BW, BD, RR,
BF
Regen Cycle Step
Times
The time duration for each regeneration step. Adjustable
from OFF and 0-199 minutes.
NOTE: If “Othr” is chosen under “Valve Type”, then
R1, R2, R3, etc, will be displayed instead