DD 2G 10.8-LD
18
CAUTION!
Protect the battery contacts when the
battery is not being used. Loose metal parts
may short-circuit the contacts –
Explosion and fire hazard!
Battery state of charge
Press the button to check the state of
charge at the state of charge indicator
LEDs.
The indicator goes out after 5 seconds.
If one of the LEDs flashes, the battery must
be recharged. If none of the LEDs light up
after the button is pressed, the battery is
faulty and must be replaced.
Direction preselection
CAUTION!
Change the direction of rotation only when
the power tool is stopped.
Move the direction preselector switch to
the required position:
Left: counterclockwise (remove screws,
release screws)
Right: clockwise (drill, insert screws,
tighten down screws)
Middle: switch-on interlock (tool change,
when working on the power tool)
Torque preselection
CAUTION!
Change the torque only when the power tool
is stopped.
Move the torque setting turning dial to the
required position.
1–17: Screwing
: Drilling
NOTE
The safety clutch is deactivated in the
Drilling setting .
Speed preselection
CAUTION!
Change the speed only when the power tool
is stopped.
Move the selector switch to the required
stage:
1: Low speed, high torque
2: High speed, low torque

Other manuals for Flex DD 2G 10.8-LD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flex DD 2G 10.8-LD and is the answer not in the manual?

Flex DD 2G 10.8-LD Specifications

General IconGeneral
BrandFlex
ModelDD 2G 10.8-LD
CategoryDrill
LanguageEnglish

Related product manuals