EasyManua.ls Logo

Flexitron Webdyn WebdynModbus - Page 11

Flexitron Webdyn WebdynModbus
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
contact@webdyn.com | webdyn.com
V1.0 subject to changes | Webdyn © by Flexitron Group
11
PROTECTION OVERLOAD Note.5 105 ~ 160% rated output power; Protection type:
Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE 27.6 ~ 32.4V
ENVIRONMENT WORKING TEMP. -20°C ~ +60°C (Refer to output load derating curve)
WORKING
HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP.,
HUMIDITY
-40°C ~ +85°C, 10 ~ 95% RH
TEMP.
COEFFICIENT
±0.03%/ (0 ~ 50) °C)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min.
each along X, Y, Z axes; Mounting: Compliance to
IEC60068-2-6
SAFETY & EMC SAFETY
STANDARDS
UL60950-1, TUV EN60950-1 approved, design refer
to EN50178
WITHSTAND
VOLTAGE
I/P-O/P: 3 KV AC
ISOLATION
RESISTANCE
I/P-O/P: 100 megohm / 500 V DC / 25 / 70% RH
EMI CONDUCTION
& RADIATION
Compliance to EN55011, EN55022 (CISPR22),
EN61204-3 Class B
HARMONIC
CURRENT
Compliance to EN61000-3-2, -3
EMS IMMUNITY Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11,
ENV50204, EN55024, EN61000-6-2, EN61204-3,
heavy industry level, criteria A
OTHERS MTBF 1172.3K hr min. MIL-HDBK-217F (25 )
DIMENSION 25*93*56mm (W*H*D)