910-0001-00-MAN-R06  FLIR Proprietary Information  Page 25 of 81  
Information contained in this document pertains to a Canadian origin product that is controlled as "dual use" by the Canadian 
government.  However, when in the United States or possessed by a US person, it may be considered a defense article from the US Government's 
perspective.  US government authorization may be required for re-transfer to a foreign person.   If you have any questions, please contact FLIR's 
Global Trade Compliance group at exportquestions@flir.com . 
 
2.2.4  Regular Scan Mode Change (applies only to R4SS-X, R6SS-X, R8SS-X and R20SS radars) 
When equipped with a pan/tilt positioner, the R4SS-X, R6SS-X, R8SS-X and R20SS supports 3 different 
regular scan modes: fixed, continuous and alternating. In order to access those modes, the radar must 
first be configured to activate the pan/tilt positioner. The parameter that enables the pan/tilt 
positioner is called "Moving_base_config" (see Figure 11). Please refer to section 2.2.10 for instructions 
on how to modify a configuration parameter. 
 
 
Figure 11 - Pan/Tilt Positioner Enable Parameter